Search icon

KARTCHNER, INC.

Company Details

Name: KARTCHNER, INC.
Jurisdiction: Idaho
Legal type: Foreign Business Corporation
Status: Active-Good Standing
Date of registration: 18 Jan 2013 (12 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 594916
Place of Formation: UTAH
File Number: 594916
Principal Address: 601 W 1700 BLDG B LOGAN, UT 84321
Mailing Address: 601 W 1700 S BLDG B LOGAN, UT 84321-8207

Agent

Name Role Address
Troy A Kartchner Agent 1075 S UTAH AVE 100, IDAHO FALLS, ID 83402

President

Name Role Address Appointed On
Troy A Kartchner President 601 W 1700 S, LOGAN, UT 84321 2020-12-03

Secretary

Name Role Address Appointed On Resigned On
C James Anderson Secretary 601 W 1700 S, LOGAN, UT 84321 2023-12-21 2023-12-21

Filing

Filing Name Filing Number Filing date
Annual Report 0006049606 2025-01-06
Annual Report 0005524282 2023-12-21
Annual Report 0005008609 2022-12-03
Registered Agent Name/Address Change (mass change) 0004591453 2022-02-03
Annual Report 0004584256 2022-01-28
Annual Report 0004083535 2020-12-03
Annual Report 0003740217 2020-01-08
Annual Report 0003405897 2019-01-22
Annual Report 0003262179 2017-12-28
Annual Report 0003262178 2017-01-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341518603 1032500 2016-06-02 THE FALLS APARTMENTS 1415 WHITEWATER DR, IDAHO FALLS, ID, 83402
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-06-02
Emphasis L: FALL, L: IDCON, N: TRENCH
Case Closed 2016-06-10

Related Activity

Type Referral
Activity Nr 1097804
Safety Yes
339597130 1032500 2014-02-13 UNIVERSITY AND S 5TH WEST, REXBURG, ID, 83440
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-02-13
Emphasis L: FALL, L: RESCON
Case Closed 2014-06-17

Related Activity

Type Complaint
Activity Nr 871654
Safety Yes
Type Inspection
Activity Nr 959738
Safety Yes

Violation Items

Citation ID 01002
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2014-04-02
Current Penalty 1800.0
Initial Penalty 2000.0
Final Order 2014-04-21
Nr Instances 1
Nr Exposed 25
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) On or about February 13, 2014, the controlling contractor, Kartchner, Inc. did not ensure that its sub-contractor protected its employees from potential falls. Two (2) sub-contracted employees were engaged in setting pump jack scaffold poles and did not don a personal fall arrest system while extended in a Snorkel aerial lift. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d) provideds that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptatlbe and is regulated under 1926.502(e): Note: Abatement certification IS NOT required for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 2500.0
Initial Penalty 2800.0
Final Order 2014-04-21
Nr Instances 1
Nr Exposed 25
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level was not protected from falling by the use of a guardrail system, safety net system, or personal fall arrest system. (a) On or about February 13, 2014, and at times prior thereto, the controlling contractor Kartchner, Inc. did not ensure that its sub-contractor protected its employees from fall hazards. Elevated work surfaces, stairs, walkways and/or balconies were not equipped with railing and exposed employees to fall hazards. Note: Abatement certification AND documentation are required for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260501 C01
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-21
Nr Instances 1
Nr Exposed 25
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(c)(1): When employees were exposed to falling objects, the employer did not have each employee wear a hard hat and did not erect toeboards, screens, canopy structures or barricades to prevent objects from falling from higher levels: (a) On or about February 13, 2014, and at times prior thereto, the controlling contractor, Kartchner, Inc. did not ensure that its sub-contractor protected its employees from overhead hazards. Wood debris was observed on a third floor exterior balcony exposing employees working below to overhead hazards. Note: Abatement certification AND documentation are required for this item.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19260502 A02
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-21
Nr Instances 1
Nr Exposed 25
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(a)(2): The employer did not provide and install all fall protection systems required by this subpart for employee(s) and did not comply with all other pertinent requirements of this subpart before employee(s) began the work that necessitates the fall protection. (a) On or about February 13, 2014, and at times prior thereto, the controlling contractor, Kartchner, Inc. did not ensure that its sub-contractor protected its employees from potential falls. Elevated work surfaces, stairs, walkways, and/or balconies were not equipped with a guard railing system and exposed employees to fall hazards. Note: Abatement certification AND documentation are required for this item.
Citation ID 01003D
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2014-04-02
Abatement Due Date 2014-04-10
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2014-04-21
Nr Instances 5
Nr Exposed 30
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): Such programs did not provide for frequent and regular inspections of the job site, materials and equipment to be made by competent persons designated by the employer: (a) On or about February 13, 2014, and at times prior thereto, the controlling contractor did not ensure sub-contracted employees were protected from ice and snow covered walking and/or working surfaces which threatened employees to hazards of slips and/or falls. (b) On or about February 13, 2014, and at times prior thereto, the controlling contractor did not ensure that sub-contracted employees were protected from potential electricution and/or shock. Electrical extension cords were found plugged into temporary power and strewn across ice and snow and lying in pools of water; some of the cords were observed wrapped with sticky tape which indicates they were worn and/or frayed. (c) On or about February 13, 2014, and at times prior thereto, the controlling contractor did not ensure that sub-contracted employees were protected from overhead hazards. Wood debris was observed on the third floor exterior balcony exposing employees working below to overhead hazards. (d) On or about February 13, 2014, and at times prior thereto, the controlling contractor did not ensure that sub-contracted employees exposed to the hazard of being ejected from the basket of an aerial lift donned a personal fall arrest system. (e) On or about February 13, 2014, and at times prior thereto, the controlling contractor did not ensure that elevated work surfaces, stairs, walkways and/or balconies were not equipped with railing and exposing sub-contracted employees to fall hazards. (Note (1): Abatement certification AND documentation are required for this item. Note (2): Competent Person: one who is capable of identifying existing and/or predictable hazards in the surroundings, or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has the authorization to take prompt corrective measures to eliminate them.
Citation ID 02001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-04-02
Abatement Due Date 2014-04-08
Current Penalty 3200.0
Initial Penalty 4000.0
Final Order 2014-04-21
Nr Instances 1
Nr Exposed 25
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Job site: On or about February 13, 2014, and times prior thereto, the controlling contractor, Kartchner, Inc. did not ensure that its sub-contractor protected its employees from falls. Sub-contracted employees were working out of an aerial lift and/or working from balconies with small hand tools while other workers worked below without donning protective head protection. Note: Abatement certification is required for this item. The Kartchner Homes, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100(a), which was contained in OSHA inspection number 313354631, citation number 1, item number 1b and was affirmed as a final order on July 9, 2010, with respect to a workplace located at 370 West 7th South, Rexburg, Idaho 83440.
Citation ID 03001
Citaton Type Other
Standard Cited 19260403 B01
Issuance Date 2014-04-02
Abatement Due Date 2014-04-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-21
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: (a) On or about February 13, 2014, and at times prior thereto, the controlling contractor, Kartchner, Inc. did not ensure that its sub-contractor protected its employees from electrical hazards. Electrical extension cords were found plugged into temporary power and strewn across ice and snow and lying in pools of water; some of the cords were observed wrapped with sticky tape which indicates they were worn and/or frayed. Note: Abatement certification IS required for this item.

Date of last update: 12 Apr 2025

Sources: Idaho Secretary of State