Search icon

KARTCHNER HOMES, INC.

Company Details

Name: KARTCHNER HOMES, INC.
Jurisdiction: Idaho
Legal type: Foreign Business Corporation
Status: Active-Good Standing
Date of registration: 02 Nov 2009 (15 years ago)
Financial Date End: 30 Nov 2025
Entity Number: 559188
Place of Formation: UTAH
File Number: 559188
Principal Address: 601 W 1700 S BUILDING B LOGAN, UT 84321
Mailing Address: 601 W 1700 S BLDG B LOGAN, UT 84321-8207

Agent

Name Role Address
Troy A Kartchner Agent 1075 S UTAH AVE 100, IDAHO FALLS, ID 83402

President

Name Role Address Appointed On
Troy A Kartchner President 601 W 1700 S, LOGAN, UT 84321 2020-11-03

Secretary

Name Role Address Appointed On Resigned On
C. James Anderson Secretary 601 W 1700 S, LOGAN, UT 84321 2023-10-03 2023-10-03

Filing

Filing Name Filing Number Filing date
Annual Report 0005920095 2024-10-03
Annual Report 0005416580 2023-10-03
Annual Report 0004989211 2022-11-10
Registered Agent Name/Address Change (mass change) 0004591452 2022-02-03
Annual Report 0004484891 2021-11-04
Annual Report 0004047821 2020-11-03
Annual Report 0003633050 2019-10-01
Annual Report 0003334941 2018-10-24
Annual Report 0003202448 2017-11-14
Annual Report 0003202447 2016-10-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341506392 1032500 2016-05-18 1415 WHITEWATER, IDAHO FALLS, ID, 83402
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-05-18
Emphasis L: FALL, L: RESCON, N: CTARGET, P: CTARGET
Case Closed 2016-11-18

Related Activity

Type Inspection
Activity Nr 1150657
Safety Yes
Type Inspection
Activity Nr 1150965
Safety Yes
Type Inspection
Activity Nr 1155356
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260405 B02
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 1100.0
Initial Penalty 2138.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: a) Building 5, unit 109 and 211: On May 18, 2016 and at times prior thereto the controlling contractor Kartchner Inc., did not ensure the sub-contractors protected their employees from incidental contact while performing construction activities near energized electrical outlets that did not have cover plates in place. Note) Certification of corrective action IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260405 D
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(d): Panel boards were not dead front: a) Building 5, unit 109 and 211: On May 18, 2016 and at times prior thereto, the controlling employer Kartchner, Inc., did not ensure the sub-contractors protected their employees while performing construction activities near 120/240 volt energized panels that were not dead front. Cardboard with cut outs for access to the energized circuit breaker(s) was used to cover the energized panels. Note) Certification of corrective action IS required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B04 II
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 1100.0
Initial Penalty 2138.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: a) Parking lot between building 5 and 6: On May 18, 2016 the controlling employer Kartchner Inc., did not ensure their sub-contractors protected their employees from an uncovered excavated hole in the asphalt parking lot. The uneven edged hole measured approximately five feet across and six feet long. Note) Certification of corrective action IS required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260502 I03
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: a) Jobsite parking lot: On May 18, 2016 and at times prior thereto the controlling employer Kartchner, Inc., did not ensure their sub-contractors protected their employees from openings cut into the asphalt parking lot. Wooden pallets covering a portion of five by six foot openings were not secured. Note) Certification of corrective action IS required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260502 I04
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a) Jobsite parking lot: On May 18, 2016 and at times prior thereto, the controlling employer Kartchner, Inc., did not ensure their sub-contractors protected their employees from openings cut into the asphalt parking lot. Wooden pallets used to cover holes for the car port footings were not marked to identify their purpose. Note) Certification of corrective action IS required for this item.
Citation ID 02001A
Citaton Type Repeat
Standard Cited 19260020 B02
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 0.0
Initial Penalty 7126.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): Such programs did not provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers: a) Building 4: On May 18, 2016 and at times prior thereto the controlling employer Kartchner Homes of Idaho did not ensure that guardrail systems were in place and maintained on the second and third floor balconies prior to allowing sub-contractors to work in these areas. b) Jobsite: On May 18, 2016 and at times prior thereto the controlling employer Kartchner Homes of Idaho did not ensure that stair rail systems were in place and maintained on the permanent stairways used by sub-contractors for access to the upper levels in each building. This included but was not limited to building 5. c) Jobsite, parking lot: On May 18, 2016 and at times prior thereto the controlling employer Kartchner Homes of Idaho did not ensure that openings cut into the asphalt parking lot were properly covered and maintained. This included openings that were partially covered, covers that not secured or marked, and an uneven edged hole left completely uncovered Kartchner, Inc., was previously cited for a violation of this occupational safety and health standard, 29 CFR 1926.20(b)(2), which was contained in OSHA inspection number 959713, citation number 1, item number 3d, and was affirmed as a final order on May 24, 2014, with respect to a workplace located at University and South 5th West, Rexburg, ID., 83440. Note) Certification and documentation of corrective actions ARE required for this item.
Citation ID 02001B
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 5400.0
Initial Penalty 0.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) Building 4: On May 18, 2016 and at time prior thereto the controlling employer Kartchner Homes of Idaho did not ensure that their employees and the employees of their sub-contractors were protected from fall hazards . Employees worked on second and third floor balconies without guardrails or other fall protection systems in place. Kartchner, Inc., was previously cited for a violation of equivalent standards 29 CFR 1926.501(b)(1) and 29 CFR 1926.502(a)(2), which were contained in OSHA inspection number 959713, citation number 1, item number 3a, and 3c. These were affirmed as a final order on May 24, 2014, with respect to a workplace located at University and South 5th West, Rexburg, ID., 83440. Note) Certification of corrective action and documentation ARE required for this item.
Citation ID 02001C
Citaton Type Repeat
Standard Cited 19261052 C01 I
Issuance Date 2016-09-23
Abatement Due Date 2016-10-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-10-26
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Jobsite: On May 18, 2016 and at times prior thereto the controlling employer Kartchner Homes of Idaho did not protect their own employees and ensure that the sub-contractors protected their employees while using permanent stairways. Permanent stairways used for access to the upper levels did not have at least one handrail in place. This included but was not limited to building 5. Kartchner, Inc., was previously cited for a violation of equivalent standards 29 CFR 1926.501(b)(1) and 29 CFR 1926.502(a)(2), which were contained in OSHA inspection number 959713, citation number 1, item number 3a, and 3c. These were affirmed as a final order on May 24, 2014, with respect to a workplace located at University and South 5th West, Rexburg, ID., 83440. Note) Certification of corrective action IS required for this item.
313354631 1032500 2010-06-08 370 WEST 7TH SOUTH, REXBURG, ID, 83440
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2010-06-08
Emphasis L: RESCON, L: FALL
Case Closed 2011-12-12

Related Activity

Type Referral
Activity Nr 200250082
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2010-06-24
Abatement Due Date 2010-07-06
Current Penalty 750.0
Initial Penalty 750.0
Nr Instances 1
Gravity 03
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2010-06-24
Abatement Due Date 2010-07-06
Current Penalty 750.0
Nr Instances 1
Gravity 03

Date of last update: 11 Apr 2025

Sources: Idaho Secretary of State