339986820
|
1032500
|
2014-09-30
|
630 WASHINGTON ST, MONTPELIER, ID, 83254
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-09-30
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2014-12-08
|
Related Activity
Type |
Inspection |
Activity Nr |
998765 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1000226 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
998785 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260034 C |
Issuance Date |
2014-10-24 |
Current Penalty |
3060.0 |
Initial Penalty |
3060.0 |
Final Order |
2014-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency: a) On September 30, 2014 Wadman Corporation did not ensure that its sub-contractors did not create hazards to which other sub-contractors would then be exposed to. A platform was built near a fixed ladder leading to the basement. This platform obstructed the means of egress for the sub-contractor working in the basement. Note) Certification of corrective action IS NOT required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260405 D |
Issuance Date |
2014-10-24 |
Current Penalty |
2295.0 |
Initial Penalty |
2295.0 |
Final Order |
2014-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(d): Panelboards were not dead front: a) On September 30, 2014 Wadman Corporation did not ensure that its sub-contractors did not create hazards to which other sub-contractors would then be exposed to. An energized electrical panel, located in the basement where other trades were working, was not dead front. Note) Certification of corrective action IS NOT required for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2014-10-24 |
Current Penalty |
2295.0 |
Initial Penalty |
3060.0 |
Final Order |
2014-11-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a) On September 30, 2014 Wadman Corporation did not ensure that its sub-contractor protected its employees from fall hazards while performing drywall activities. Sub-contractor employees were exposed to an 11' fall to concrete. Note) Certification of corrective action IS NOT required for this item. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2014-10-24 |
Current Penalty |
0.0 |
Initial Penalty |
2295.0 |
Final Order |
2014-11-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On September 30, 2014 Wadman Corporation did not ensure that its sub-contractor protected their employees while performing painting activities. A sub-contractor employee worked from the top step of a self-supporting ladder. Note) Certification of corrective action IS NOT required for this item. |
|
|
308337427
|
1032500
|
2005-02-17
|
4335 YELLOWSTONE, CHUBBUCK, ID, 83202
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2005-02-17
|
Emphasis |
L: FALL
|
Case Closed |
2005-04-04
|
Related Activity
Type |
Referral |
Activity Nr |
200241255 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2005-03-01 |
Abatement Due Date |
2005-03-07 |
Current Penalty |
1300.0 |
Initial Penalty |
2500.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
|
308337021
|
1032500
|
2005-01-28
|
4335 YELLOWSTONE, CHUBBUCK, ID, 83202
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2005-01-28
|
Emphasis |
L: FALL
|
Case Closed |
2005-04-04
|
Related Activity
Type |
Referral |
Activity Nr |
200241123 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2005-02-25 |
Abatement Due Date |
2005-03-07 |
Current Penalty |
1600.0 |
Initial Penalty |
3000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
|
300203148
|
1032500
|
1997-01-23
|
4155 YELLOWSTONE, CHUBBUCK, ID, 83202
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1997-01-23
|
Emphasis |
L: FALL
|
Case Closed |
1997-02-19
|
Related Activity
Type |
Complaint |
Activity Nr |
200223493 |
Safety |
Yes |
|
|