Search icon

VISSER BUILDING CO., L.C.

Company Details

Name: VISSER BUILDING CO., L.C.
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 07 Apr 1998 (27 years ago)
Financial Date End: 30 Apr 2026
Entity Number: 32434
Place of Formation: IDAHO
File Number: 32434
ZIP code: 83704
County: Ada County
Principal Address: 8312 NORTHVIEW ST STE 120 BOISE, ID 83704
Mailing Address: STE 120 8312 W NORTHVIEW ST BOISE, ID 83704-7188

Agent

Name Role Address
BRIAN VISSER Agent 8312 NORTHVIEW ST, STE 120, BOISE, ID 83704

Member

Name Role Address Appointed On Resigned On
Brian Visser Member 8312 W. NORTHVIEW STREET, BOISE, ID 83704 2024-06-04 2024-06-04
William F Gallagher Member 8312 W. NORTHVIEW STREET, BOISE, ID 83704 2021-03-03 No data
Robert Hunter Member 8312 W. NORTHVIEW STREET, STE 120, BOISE, ID 83704 2024-06-04 No data

Filing

Filing Name Filing Number Filing date
Annual Report 0006136707 2025-03-03
Annual Report 0005758808 2024-06-04
Annual Report 0005133648 2023-03-03
Annual Report 0004628303 2022-03-03
Annual Report 0004188319 2021-03-03
Annual Report 0003793116 2020-03-03
Annual Report 0003475951 2019-04-11
Annual Report 0001048334 2018-02-28
Annual Report 0001048320 2017-04-17
Annual Report 0001048318 2016-05-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345162721 1032500 2021-02-24 505 WEST BANNOCK STREET, BOISE, ID, 83702
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-02-24
Emphasis N: CTARGET, P: CTARGET
Case Closed 2021-07-18

Related Activity

Type Inspection
Activity Nr 1516277
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260020 B01
Issuance Date 2021-05-03
Abatement Due Date 2021-05-20
Current Penalty 1843.0
Initial Penalty 3686.0
Final Order 2021-05-24
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not have an effective system in place to correct hazards to which their subcontractors were exposed. These hazards include but may not be limited to fall hazards up to 16 feet, on and around the interior spiral stairway. b) On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not have an effective system in place to correct hazards to which their subcontractors were exposed. These hazards include but may not be limited to maintaining proper machine guarding on table saws used to cut finish woodwork. Note) Abatement certification and documentation are required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2021-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-05-24
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not ensure sub-contractors protected their employees from fall hazards. Sub-contractor employees performed work, including but not limited to finish carpentry work, on or near the interior spiral stairway landing without a fall protection system in place. This exposed the employee(s) to a 16 foot fall hazard the floor below. Note) Corrected during inspection.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261052 C04
Issuance Date 2021-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-05-24
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4): Mid rails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stair rail system and the stairway steps: a) Interior spiral stairway: On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not ensure sub-contractors protected their employees from fall hazards while working on the interior spiral stairway. Top rails and mid rails were missing at various locations along the stair rail system. Note) Corrected during inspection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260304 H01
Issuance Date 2021-05-03
Current Penalty 1317.0
Initial Penalty 2633.0
Final Order 2021-05-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood that meets all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws: a)Jobsite: On February 24, 2021; the controlling employer, Visser Building Company, did not ensure a sub-contractor protected their employees from amputation hazards while performing finish carpentry work. An employee used a 10 inch Metabo table saw with the upper blade guard removed. Note) Corrected during inspection
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260304 I01
Issuance Date 2021-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-05-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(i)(1):Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed the portion of the saw above the table and that portion of the saw above the material being cut: a) Jobsite: On February 24, 2021; the controlling employer, Visser Building Co., L.C., did not ensure a sub-contractor protected their employees from amputation hazards while performing finish carpentry work. An employee used a 10 inch Metabo table saw with the upper blade guard removed. Note) Fixed during inspection.