Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-03-28
|
Case Closed |
2017-10-12
|
Related Activity
Type |
Inspection |
Activity Nr |
1218782 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2017-04-04 |
Current Penalty |
1400.0 |
Initial Penalty |
2716.0 |
Final Order |
2017-05-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about March 15, 2017 or prior thereto employees were working within 1-5' of an unguarded window frame on the second floor. The bottom of the window frame was measured at 22" from the second floor and 14.6' from the ground outside. NOTE: Abatement certification IS NOT required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 II |
Issuance Date |
2017-04-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-05-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. a) On or about March 15, 2017 employees were working within 1-5' of holes in the second floor. Two 16"x16" holes located on the second floor adjacent to the west wall were left unguarded while employees worked to move the furnace. NOTE: Abatement certification IS NOT required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2017-04-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-05-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) On or about March 17, 2017 or prior thereto employees were working within 10-15' of wall openings on the second floor. Metal studs with openings measuring 22" were missing guardrails. NOTE: Abatement certification IS NOT required for this item. |
|
|