Name: | SUNRISE CONSTRUCTION & ROOFING |
Jurisdiction: | Idaho |
Legal type: | General Partnership (D) |
Status: | Active-Current |
Date of registration: | 08 Mar 2016 (9 years ago) |
Expiration date: | 12 Feb 2026 |
Entity Number: | 9217 |
Place of Formation: | IDAHO |
File Number: | 0000009217 |
ZIP code: | 83843 |
County: | Latah County |
Principal Address: | 2518 E D ST MOSCOW, ID 83843-9510 |
Mailing Address: | 2518 EAST D ST MOSCOW, ID 83843 |
Filing Name | Filing Number | Filing date |
---|---|---|
Statement of Expiration Extension for Partnership Authority (GP) | 0004173363 | 2021-02-11 |
Initial Filing | 0000009217 | 2016-03-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345945158 | 1032500 | 2022-05-05 | 515 SOUTH VIEW, MOSCOW, ID, 83843 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1892435 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2022-05-25 |
Abatement Due Date | 2022-06-01 |
Current Penalty | 2200.0 |
Initial Penalty | 4351.0 |
Final Order | 2022-06-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 a) On May 5, 2022 and at times prior; an employee performed roofing activities on a 8 in 12 pitched roof without fall protection. The employee was exposed to fall hazards ranging from 10 to approximately 21 feet to the ground below. Note) Certification of corrective action is required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A02 III |
Issuance Date | 2022-05-25 |
Abatement Due Date | 2022-06-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2022-06-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) On May 5, 2022 and at times prior: an employee performing roofing activities on a 8 in 12 pitched roof had not been trained to recognize the hazards of working without fall protection or what was needed to minimize the hazards. Note) Certification of corrective action is required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2022-05-25 |
Abatement Due Date | 2022-06-01 |
Current Penalty | 1300.0 |
Initial Penalty | 2486.0 |
Final Order | 2022-06-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On May 5, 2022 and at times prior; an employee used an extension ladder to access the roof of a single story residential building. The ladder did not extend beyond the eave of the roof. Note) Abatement certification is required for this item. |
Date of last update: 22 Sep 2024
Sources: Idaho Secretary of State