Name: | SORANCO BEAN PRODUCTS, INC. |
Jurisdiction: | Idaho |
Legal type: | General Business Corporation (D) |
Status: | Active-Good Standing |
Date of registration: | 13 Jul 1949 (76 years ago) |
Financial Date End: | 31 Jul 2025 |
Entity Number: | 86726 |
Place of Formation: | IDAHO |
File Number: | 86726 |
Mailing Address: | TONI CARLTON PO BOX 963 TWIN FALLS, ID 83303-0963 |
Name | Role | Address |
---|---|---|
JAMES R SORAN | Agent | 150 SOUTH PARK AVENUE WEST, TWIN FALLS, ID 83301 |
Name | Role | Address | Appointed On |
---|---|---|---|
James R Soran | President | PO BOX 2915, TWIN FALLS, ID 83301 | 2020-07-16 |
Name | Role | Address | Appointed On |
---|---|---|---|
Toni R Carlton | Secretary | 4174 N 950 E, BUHL, ID 83316 | 2023-08-03 |
Filing Name | Filing Number | Filing date |
---|---|---|
Articles of Amendment | 0006015676 | 2024-12-18 |
Annual Report | 0005810579 | 2024-07-08 |
Annual Report | 0005346656 | 2023-08-03 |
Annual Report | 0004787058 | 2022-06-20 |
Annual Report | 0004336055 | 2021-07-07 |
Annual Report | 0003941192 | 2020-07-16 |
Annual Report | 0003547382 | 2019-06-20 |
Annual Report | 0001243248 | 2018-06-11 |
Annual Report | 0001243246 | 2017-05-19 |
Annual Report | 0001243244 | 2016-06-13 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339818809 | 1032500 | 2014-06-11 | 150 SOUTH PARK AVE. WEST, TWIN FALLS, ID, 83301 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100147 C01 |
Issuance Date | 2014-09-09 |
Abatement Due Date | 2014-10-03 |
Current Penalty | 1190.0 |
Initial Penalty | 2380.0 |
Final Order | 2014-10-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Bean bagging area: The company does not have a program and did not have a specific energy control procedure in place to isolate energy sources when the employee performing required service or maintenance on plant equipment, specifically on the bag sewing machine that he only used the machine start-stop control, and did not isolate the machine at the main power source. Note: Abatement certification is required for this item |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100212 B |
Issuance Date | 2014-09-09 |
Abatement Due Date | 2014-10-03 |
Current Penalty | 892.5 |
Initial Penalty | 1785.0 |
Final Order | 2014-10-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Plant maintenance shop: Table top grinder was held in place by only a welder's C-clamp, instead of securely bolted to prevent movement. Note: Abatement certification is required for this item. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100215 B09 |
Issuance Date | 2014-09-09 |
Abatement Due Date | 2014-10-03 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-10-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Plant maintenance shop: Bench grinder missing it's adjustable tongue guard, preventing adjustment of the guard and wheel clearance to not exceed 1/4 inch. Note: Abatement certification is required for this item. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100219 C04 I |
Issuance Date | 2014-09-09 |
Abatement Due Date | 2014-10-03 |
Current Penalty | 892.5 |
Initial Penalty | 1785.0 |
Final Order | 2014-10-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Mill House: Mill drive shaft extended more than 1/2 it's diameter outside it's enclosure and was not guarded. Note: Abatement certification is required for this item. |
Date of last update: 21 Apr 2025
Sources: Idaho Secretary of State