Search icon

SORANCO BEAN PRODUCTS, INC.

Company Details

Name: SORANCO BEAN PRODUCTS, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Active-Good Standing
Date of registration: 13 Jul 1949 (76 years ago)
Financial Date End: 31 Jul 2025
Entity Number: 86726
Place of Formation: IDAHO
File Number: 86726
Mailing Address: TONI CARLTON PO BOX 963 TWIN FALLS, ID 83303-0963

Agent

Name Role Address
JAMES R SORAN Agent 150 SOUTH PARK AVENUE WEST, TWIN FALLS, ID 83301

President

Name Role Address Appointed On
James R Soran President PO BOX 2915, TWIN FALLS, ID 83301 2020-07-16

Secretary

Name Role Address Appointed On
Toni R Carlton Secretary 4174 N 950 E, BUHL, ID 83316 2023-08-03

Filing

Filing Name Filing Number Filing date
Articles of Amendment 0006015676 2024-12-18
Annual Report 0005810579 2024-07-08
Annual Report 0005346656 2023-08-03
Annual Report 0004787058 2022-06-20
Annual Report 0004336055 2021-07-07
Annual Report 0003941192 2020-07-16
Annual Report 0003547382 2019-06-20
Annual Report 0001243248 2018-06-11
Annual Report 0001243246 2017-05-19
Annual Report 0001243244 2016-06-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339818809 1032500 2014-06-11 150 SOUTH PARK AVE. WEST, TWIN FALLS, ID, 83301
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-06-11
Emphasis L: FORKLIFT, P: GRAIN, N: DUSTEXPL, L: GRAIN
Case Closed 2014-10-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2014-09-09
Abatement Due Date 2014-10-03
Current Penalty 1190.0
Initial Penalty 2380.0
Final Order 2014-10-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Bean bagging area: The company does not have a program and did not have a specific energy control procedure in place to isolate energy sources when the employee performing required service or maintenance on plant equipment, specifically on the bag sewing machine that he only used the machine start-stop control, and did not isolate the machine at the main power source. Note: Abatement certification is required for this item
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2014-09-09
Abatement Due Date 2014-10-03
Current Penalty 892.5
Initial Penalty 1785.0
Final Order 2014-10-07
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Plant maintenance shop: Table top grinder was held in place by only a welder's C-clamp, instead of securely bolted to prevent movement. Note: Abatement certification is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2014-09-09
Abatement Due Date 2014-10-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-10-07
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Plant maintenance shop: Bench grinder missing it's adjustable tongue guard, preventing adjustment of the guard and wheel clearance to not exceed 1/4 inch. Note: Abatement certification is required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100219 C04 I
Issuance Date 2014-09-09
Abatement Due Date 2014-10-03
Current Penalty 892.5
Initial Penalty 1785.0
Final Order 2014-10-07
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Mill House: Mill drive shaft extended more than 1/2 it's diameter outside it's enclosure and was not guarded. Note: Abatement certification is required for this item.