342723558
|
1032500
|
2017-10-17
|
BROWN SKY CORNER LOGGING SITE, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-10-17
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2018-09-27
|
Related Activity
Type |
Inspection |
Activity Nr |
1271303 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1272344 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100266 H02 VI |
Issuance Date |
2017-11-13 |
Current Penalty |
3993.0 |
Initial Penalty |
7986.0 |
Final Order |
2017-12-05 |
Nr Instances |
5 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(h)(2)(vi): The backcut did not leave sufficient hinge wood to hold the tree to the stump during most of its fall so that the hinge is able to guide the tree's fall in the intended direction. a) On or about August 2, 2017 and at times prior thereto trees were felled manually with a chain saw where a back cut was even with the face cut and did not contain sufficient hinge wood. NOTE-Abatement certification is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100266 H02 VII |
Issuance Date |
2017-11-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-05 |
Nr Instances |
15 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(h)(2)(vii): The backcut was not above the level of the horizontal facecut in order to provide an adequate platform to prevent kickback. a) On or about August 2, 2017 and at times prior thereto trees were felled manually with a chain saw where a back cut was even with, or below the face cut. NOTE-Abatement certification is required for this item. |
|
|
342723442
|
1032500
|
2017-10-17
|
SHOP, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-10-17
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2018-09-27
|
Related Activity
Type |
Inspection |
Activity Nr |
1271303 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1272355 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2017-11-13 |
Abatement Due Date |
2017-12-08 |
Current Penalty |
3993.0 |
Initial Penalty |
7986.0 |
Final Order |
2017-12-05 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) On or about October 17, 2017 and at times prior thereto, the shop circuit breaker panel which provided power throughout the shop, had eight circuit breakers which were not labeled to identify disconnecting means. Note-Abatement certification and documentation are required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2017-11-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) On or about October 17, 2017 and at times prior thereto, employees were working on a waste oil heater, exposed to live 110V electrical wires, where no covers were installed on three junction boxes to guard against contact. Note-Abatement certification is required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100333 A01 |
Issuance Date |
2017-11-13 |
Abatement Due Date |
2017-12-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not deenergized before the employee worked on or was near to them: a) On or about October 17, 2017 and at times prior thereto, the employer did not assure the 110 volt electrical lines, which provided power to the waste oil heater, were disconnected from all electrical energy sources when employees were performing maintenance. Note-Abatement certification and documentation are required for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100333 B02 III A |
Issuance Date |
2017-11-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed: a) On or about October 17, 2017 and at times prior thereto, employees were performing maintenance on a waste oil heater with exposed live 110 volt electrical lines, where no lock or tag was in place at the disconnecting means. Note-Abatement certification and documentation are required for this item. |
|
|
342713039
|
1032500
|
2017-10-17
|
BROWN SKY CORNER, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-10-17
|
Emphasis |
L: LOGGING, P: LOGGING
|
Case Closed |
2017-10-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1272355 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1272344 |
Safety |
Yes |
|
|
334288917
|
1032500
|
2012-05-09
|
201 HWY 95, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-05-10
|
Emphasis |
N: SSTARG11
|
Case Closed |
2012-12-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19040007 B03 |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-11-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
30 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.7(b)(3): How do I record a work-related injury or illness that results in days away from work? When an injury or illness involves one or more days away from work, you must record the injury or illness on the OSHA 300 Log with a check mark in the space for cases involving days away and an entry of the number of calendar days away from work in the number of days column. If the employee is out for an extended period of time, you must enter an estimate of the days that the employee will be away, and update the day count when the actual number of days is known. a) For the calendar year 2011 OSHA record keeping log case # 1, the employer did not record any days away for a case classified as one with days away. Note: Abatement certification is required. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19100147 C04 I |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-12-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section. a) In the Shop, on or about May 9, 2012, and at times prior thereto, the employer did not have an implemented or complete lock out/ tag out program for equipment such as Yarders, skidders, dozers, loaders, log trucks, lathe, milling machine. Note: Abatement certification is required. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19100147 C06 II |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-12-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(ii): The employer did not certify that a periodic/annual inspection of lock out tag out procedures had been performed a) In the Shop, on or about May 9, 2012, and at times prior thereto, the employer did not certify the completion of at least an annual review of lock out/ tag out procedures. Note: Abatement certification is required. |
|
Citation ID |
01002C |
Citaton Type |
Other |
Standard Cited |
19100147 C07 I |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-12-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees. a) In the Shop, on or about May 9, 2012, and at times prior thereto, the employer did not provide training and/or instructions to employees (affected, authorized or other) in the requirements of the standard. Note: Abatement certification is required. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100215 B09 |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
2 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top was greater than one-fourth inch: a) In the shop on or about May 09, 2012, and at times prior thereto, the tongue guard on the Chicago Industry bench grinder, model 750 3/4 HP was 3/4 Inch from the 7 inch wheel. b) In the shop on or about May 09, 2012, and at times prior thereto, the tongue guard on the Delta bench grinder, 4/5 HP was ? inch from the 8 inch wheel. Note: Abatement certification is required. |
|
Citation ID |
01004A |
Citaton Type |
Other |
Standard Cited |
19100244 A01 II |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
7 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.244(a)(1)(ii): The rated load was not legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means. a) In the Shop, on or about May 9, 2012, and at times prior thereto, the Big Red Air over hydraulic jack lacked load rating marks. b) In the Shop, on or about May 9, 2012, and at times prior thereto, the Northern jack lacked load rating marks. c) In the Shop, on or about May 9, 2012, and at times prior thereto, the Oraange Air over hydraulic jack lacked load rating marks. d) In the Shop, on or about May 9, 2012, and at times prior thereto, the Northern Bottle jack lacked load rating marks. e) In the Shop, on or about May 9, 2012, and at times prior thereto, the NAPA bottle jack model 94-229 jack lacked load rating marks. f) In the Shop, on or about May 9, 2012, and at times prior thereto, theNAPA Bottle jack model 791-6420 lacked load rating marks. g) In the Shop, on or about May 9, 2012, and at times prior thereto, theYellow hydraulic jack Model G3AD132 lacked load rating marks. Note: Abatement certification is required. |
|
Citation ID |
01004B |
Citaton Type |
Other |
Standard Cited |
19100244 A02 VI A |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.244(a)(2)(vi)(a): Hydraulic jacks in constant or intermittent use at one locality were not inspected at least once every 6 months: a) In the shop, on or about May 9, 2012, and at times prior thereto, the employer did not inspect, and document the results of the inspection on hydraulic bottle jacks, hydraulic floor jacks, and air over hydraulic jacks. Note: Abatement certification is required. |
|
Citation ID |
01005 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 II |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-11-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed. a) In the shop on or about May 09, 2012, and at times prior thereto, electrical distribution panel A was missing three covers where circuit breakers belong. Note: Abatement certification is required. |
|
Citation ID |
01006A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-12-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: a) In the Office and shop, on or about May 9, 2012, and at times prior thereto, the employer did not implement an effective hazard communication program to include chemicals such as fuels, lubricants, paints, brake shoes, and liquid petroleum gas. Note: Abatement certification is required. |
|
Citation ID |
01006B |
Citaton Type |
Other |
Standard Cited |
19101200 E01 I |
Issuance Date |
2012-10-29 |
Abatement Due Date |
2012-12-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1)(i): A list of the hazardous chemicals known to be present was not prepared using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); a) In the shop on or about May 09, 2012, and at times prior thereto, the employer did not have or maintain a list of chemicals found in the shop such as Oxygen, acetylene gas, carbon dioxide, cutting fluid, lubricating oils, brake shoes. Note: Abatement certification is required. |
|
|
308341536
|
1032500
|
2005-08-31
|
FLAT CREEK ROAD JOB, DONNELLY, ID, 83615
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-08-31
|
Emphasis |
L: LOGGING, N: SSTARG04
|
Case Closed |
2005-10-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100266 D07 I |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-09-15 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
308341502
|
1032500
|
2005-08-30
|
201 HWY 95, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2005-08-31
|
Emphasis |
L: LOGGING, N: SSTARG04
|
Case Closed |
2005-12-07
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2005-09-02 |
Abatement Due Date |
2005-11-15 |
Current Penalty |
525.0 |
Initial Penalty |
2500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100095 G06 |
Issuance Date |
2005-09-02 |
Abatement Due Date |
2005-10-21 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100095 G07 II |
Issuance Date |
2005-09-02 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100095 G08 I |
Issuance Date |
2005-09-02 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19100095 M02 IIE |
Issuance Date |
2005-09-02 |
Abatement Due Date |
2005-11-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040010 A |
Issuance Date |
2005-09-02 |
Abatement Due Date |
2005-10-05 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
|
308341494
|
1032500
|
2005-08-30
|
201 HWY 95, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2005-08-31
|
Emphasis |
L: LOGGING, N: SSTARG04
|
Case Closed |
2006-02-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101200 E02 I |
Issuance Date |
2005-09-01 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2005-09-01 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
52 |
Gravity |
01 |
|
|
308341510
|
1032500
|
2005-08-30
|
201 HWY 95, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-08-31
|
Emphasis |
L: LOGGING, N: SSTARG04
|
Case Closed |
2005-10-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100266 D01 III |
Issuance Date |
2005-09-02 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
308341544
|
1032500
|
2005-08-30
|
201 HWY 95, NEW MEADOWS, ID, 83654
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-08-31
|
Emphasis |
N: SSTARG04
|
Case Closed |
2006-01-27
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100023 C02 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-12-15 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100023 D01 II |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-12-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-10-05 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-09-21 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-11-15 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 I |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-11-15 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100157 E03 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100169 A02 I |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2006-01-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100169 B03 I |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-11-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100212 B |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-11-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100215 A02 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100215 A04 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02007 |
Citaton Type |
Other |
Standard Cited |
19100215 B09 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02008 |
Citaton Type |
Other |
Standard Cited |
19100304 F04 |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-09-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02009 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 I |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02010 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2005-09-09 |
Abatement Due Date |
2005-10-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
218346260
|
1032500
|
1981-06-24
|
CALF PEN SALE NORTH OF HORNET, Council, ID, 83612
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1981-06-24
|
Emphasis |
L: LOCAL
|
Case Closed |
1981-06-29
|
|
218345221
|
1032500
|
1980-08-21
|
HORSE THIEF 5 & 6 SALE 20 MI E, Cascade, ID, 83611
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1980-08-21 |
Case Closed |
1984-03-10 |
|
218345213
|
1032500
|
1980-08-21
|
FOOL HEN FEE SALE 20 MILES NE, Cascade, ID, 83611
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1980-08-21 |
Case Closed |
1984-03-10 |
|
218345205
|
1032500
|
1980-08-21
|
BRUNDAGE MT SALE 15 MILES NW, Mccall, ID, 83638
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1980-08-21 |
Case Closed |
1984-03-10 |
|
218344331
|
1032500
|
1979-11-16
|
FOOLHEN SALE, Donnelly, ID, 83615
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1979-11-16 |
Case Closed |
1979-12-10 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100106 D02 I |
Issuance Date |
1979-12-06 |
Abatement Due Date |
1980-01-07 |
Nr Instances |
1 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100180 D06 |
Issuance Date |
1979-12-06 |
Abatement Due Date |
1980-01-07 |
Nr Instances |
1 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100180 G01 |
Issuance Date |
1979-12-06 |
Abatement Due Date |
1980-01-07 |
Nr Instances |
1 |
|
|
218344281
|
1032500
|
1979-11-09
|
BOULDER CREEK SALE, Cascade, ID, 83611
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1979-11-13 |
Case Closed |
1980-01-10 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100106 D02 I |
Issuance Date |
1979-12-06 |
Abatement Due Date |
1980-01-07 |
Nr Instances |
1 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100180 B02 |
Issuance Date |
1979-12-06 |
Abatement Due Date |
1980-01-07 |
Nr Instances |
1 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100180 D06 |
Issuance Date |
1979-12-06 |
Abatement Due Date |
1980-01-07 |
Nr Instances |
1 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19100180 G01 |
Issuance Date |
1979-12-06 |
Abatement Due Date |
1980-01-07 |
Nr Instances |
1 |
|
|