Name: | MARIPOSA LABS, LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 10 Dec 2002 (22 years ago) |
Financial Date End: | 31 Dec 2025 |
Entity Number: | 78738 |
Place of Formation: | IDAHO |
File Number: | 78738 |
Principal Address: | PO BOX 1779 BOISE, ID 83701 |
Mailing Address: | PO BOX 1779 BOISE, ID 83701-1779 |
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MARIPOSA LABS CASH BALANCE PLAN | 2023 | 481288806 | 2024-10-07 | MARIPOSA LABS, LLC | 26 | |||||||||||||
|
||||||||||||||||||
MARIPOSA LABS LLC 401(K) PROFIT SHARING PLAN | 2023 | 481288806 | 2024-10-08 | MARIPOSA LABS, LLC | 34 | |||||||||||||
|
||||||||||||||||||
MARIPOSA LABS CASH BALANCE PLAN | 2022 | 481288806 | 2023-10-02 | MARIPOSA LABS, LLC | 26 | |||||||||||||
|
||||||||||||||||||
MARIPOSA LABS LLC 401(K) PROFIT SHARING PLAN | 2022 | 481288806 | 2023-07-27 | MARIPOSA LABS, LLC | 33 | |||||||||||||
|
||||||||||||||||||
MARIPOSA LABS LLC 401(K) PROFIT SHARING PLAN | 2021 | 481288806 | 2022-05-03 | MARIPOSA LABS, LLC | 27 | |||||||||||||
|
||||||||||||||||||
MARIPOSA LABS CASH BALANCE PLAN | 2021 | 481288806 | 2022-06-21 | MARIPOSA LABS, LLC | 29 | |||||||||||||
|
Name | Role | Address |
---|---|---|
CLAUDE M GILLESPIE III | Agent | 270 E 50TH STREET, BOISE, ID 83714 |
Name | Role | Address | Appointed On | Resigned On |
---|---|---|---|---|
Hollis J Brookover | Member | 270 E 50TH STREET, BOISE, ID 83714 | 2023-11-08 | 2023-11-08 |
Claude M Gillespie | Member | 270 E 50TH STREET, BOISE, ID 83714 | 2021-11-19 | No data |
Claude M Gillespie III | Member | 270 E 50TH STREET, BOISE, ID 83714 | 2020-11-18 | No data |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005986339 | 2024-11-18 |
Annual Report | 0005472257 | 2023-11-08 |
Annual Report | 0005082485 | 2023-01-26 |
Annual Report | 0004502911 | 2021-11-19 |
Annual Report | 0004070377 | 2020-11-18 |
Annual Report | 0003707813 | 2019-12-12 |
Annual Report | 0003367324 | 2018-12-10 |
Annual Report | 0001212977 | 2017-11-09 |
Annual Report | 0001212975 | 2016-11-30 |
Annual Report | 0001212973 | 2015-11-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343252920 | 1032500 | 2018-06-26 | 270 E 50TH ST, GARDEN CITY, ID, 83714 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1351045 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 B |
Issuance Date | 2018-07-09 |
Current Penalty | 2308.6 |
Initial Penalty | 3298.0 |
Final Order | 2018-08-01 |
Nr Instances | 4 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving. a) On or about June 26, 2018 or prior thereto, Production Area: Low pressure steam tank #6 was not anchored. b) On or about June 26, 2018 or prior thereto, Production Area: Low pressure steam tank #7 was not anchored. c) On or about June 26, 2018 or prior thereto, Production Area: Low pressure steam tank #9 was not anchored. d) On or about June 26, 2018 or prior thereto, Production Area: Low pressure steam tank #10 was not anchored. NOTE: Abatement certification is NOT required for this item. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100132 D02 |
Issuance Date | 2018-07-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-08-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. a) On or about June 26, 2018, or prior thereto: The employer had not completed a certified personal protective equipment assessment. Eye and face protection are required in the Production Area, Packaging, and the QA Lab. NOTE: Abatement certification is NOT required for this item. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100147 C06 I |
Issuance Date | 2018-07-09 |
Abatement Due Date | 2018-08-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-08-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about June 26, 2018 or prior thereto: A periodic inspection of the employer's energy control procedures had not been completed. Lockout procedures have been conducted on Tank #3 in Production, and the Oden Filler. Pneumatic and electrical lockouts have been performed. NOTE: Abatement certification IS required for this item. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19100178 L04 III |
Issuance Date | 2018-07-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-08-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance had not been conducted at least once every three years. a) On or about June 26, 2018 or prior thereto: Employees operate Crown Powered Industrial Trucks Model RC 3020-40, Serial Number 1A243806; and Model 35RCTT, Serial Number 1A159538. Employee operators were not trained at least once every three years. NOTE: Abatement certification is NOT required for this item. |