Search icon

TWO BROTHERS CONSTRUCTION AND RENOVATION, INC.

Company Details

Name: TWO BROTHERS CONSTRUCTION AND RENOVATION, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 19 May 2016 (9 years ago)
Financial Date End: 31 May 2021
Date dissolved: 14 Aug 2021
Entity Number: 627677
Place of Formation: IDAHO
File Number: 627677
ZIP code: 83401
County: Bonneville County
Mailing Address: 3788 N 5TH E BLDG C IDAHO FALLS, ID 83401-1146

Agent

Name Role Address
Dru M Guthrie Agent 890 OXFORD DRIVE, IDAHO FALLS, ID 83401

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0004384937 2021-08-14
Annual Report 0003830323 2020-04-03
Annual Report 0003500418 2019-05-01
Change of Registered Office/Agent/Both (by Entity) 0003441690 2019-03-05
Registered Agent Resignation from an Entity 0003425999 2019-02-08
Annual Report 0003297597 2018-06-20
Statement of Change of Business Mailing Address 0003297596 2018-04-11
Annual Report 0003297595 2017-06-20
Initial Filing 0000627677 2016-05-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342402989 1032500 2017-06-14 PINFIRE CREEK, AMMON, ID, 83406
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-06-14

Related Activity

Type Referral
Activity Nr 1228860
Safety Yes
342364247 1032500 2017-05-22 PINFIRE CREEK, AMMON, ID, 83406
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-05-22
Case Closed 2022-06-10

Related Activity

Type Referral
Activity Nr 1221614
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2017-07-14
Abatement Due Date 2017-08-09
Current Penalty 8873.0
Initial Penalty 8873.0
Final Order 2017-08-16
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. (b) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were installing fascia of a single family home. Note: Abatement documentation and certification required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 C02 IV
Issuance Date 2017-07-14
Abatement Due Date 2017-08-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-16
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. (b) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were installing fascia of a single family home. Note: Abatement documentation and certification is required.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 C02 V
Issuance Date 2017-07-14
Abatement Due Date 2017-08-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and the fork-lift was moved horizontally while the platform was occupied: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. Note: Abatement documentation and certification is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2017-07-14
Abatement Due Date 2017-08-09
Current Penalty 8873.0
Initial Penalty 8873.0
Final Order 2017-08-16
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. (b) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were installing fascia of a single family home. Note: Abatement documentation and certification is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260602 D
Issuance Date 2017-07-14
Abatement Due Date 2017-08-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(d): The employer did not ensure that each employee operating a powered industrial vehicle had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178. and as referenced by the note contained in 1926.602(d). (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. Note: Abatement documentation and certification is required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-07-14
Abatement Due Date 2017-08-09
Current Penalty 8873.0
Initial Penalty 8873.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were walking along the top plate of a single family home. Note: Abatement certification and documentation is required for this item.

Date of last update: 20 Mar 2025

Sources: Idaho Secretary of State