Search icon

STATELINE CONSTRUCTION, LLC

Company Details

Name: STATELINE CONSTRUCTION, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 21 May 2001 (24 years ago)
Financial Date End: 31 May 2025
Entity Number: 60335
Place of Formation: IDAHO
File Number: 60335
ZIP code: 83501
County: Nez Perce County
Principal Address: TERRY ELDRED 3208 10TH STREET LEWISTON, ID 83501
Mailing Address: 3208 10TH ST LEWISTON, ID 83501-4813

Agent

Name Role Address
TERRY ELDRED Agent 3208 10TH STREET, LEWISTON, ID 83501

Member

Name Role Address Appointed On Resigned On
BRANDON LEE ELDRED Member 518 BURRELL AVE, LEWISTON, ID 83501 2024-05-30 No data
TERRY ALLEN ELDRED Member 3208 10TH STREET, LEWISTON, ID 83501 2024-05-30 No data
Terry A Eldred Member 518 BURRELL AVE, LEWISTON, ID 83501 2021-07-02 2023-06-06
JASON ALLEN ELDRED Member 2257 RESERVOIR RD, CLARKSTON, WA 99403 2024-05-30 No data

Filing

Filing Name Filing Number Filing date
Annual Report 0005751274 2024-05-30
Amendment to Certificate 0005655235 2024-03-20
Change of Registered Office/Agent/Both (by Entity) 0005655202 2024-03-20
Statement of Change of Business Mailing Address 0005655156 2024-03-20
Annual Report 0005269243 2023-06-06
Annual Report 0004777403 2022-06-09
Annual Report 0004330293 2021-07-02
Annual Report 0003864720 2020-05-04
Annual Report 0003528755 2019-05-31
Annual Report 0001149672 2018-05-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342207511 1032500 2017-03-28 731 8TH STREET, LEWISTON, ID, 83501
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-03-28
Case Closed 2018-01-29

Related Activity

Type Referral
Activity Nr 1196697
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2017-04-13
Abatement Due Date 2017-04-19
Current Penalty 1500.0
Initial Penalty 2716.0
Final Order 2017-08-30
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: a) South side of building: On or about March 28, 2017 and at times prior thereto employees performing re-roofing activities on a 16 in 12 pitched roof, positioned tubular welded scaffold systems at various locations along the roofs eave. The scaffold was used as a flat work surface for the roofing work above. A guardrail or other fall protection system was not in place, exposing the employees to fall hazards up to 19 and a half feet to the ground below. Note) Certification of corrective action is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2017-04-13
Abatement Due Date 2017-05-15
Current Penalty 2500.0
Initial Penalty 3803.0
Final Order 2017-08-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) North side of building: On March 28, 2017 and at times prior thereto an employees was staging roofing materials on a flat roof deck. A warning line or another type of fall protection system was not in place. The employee was exposed to a 13 foot fall to the ground below. Note) Certification and documentation of corrective action is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2017-04-13
Abatement Due Date 2017-05-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-30
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toe boards, safety net systems, or personal fall arrest systems: a) North side of building: On or about March 28, 2017 and at times prior thereto employees performed re-roofing activities on a 16 in 12 pitch roof without a fall protection system in place. Employee(s) were exposed to fall hazards ranging from approximately 11 feet to the eave/scaffold platform below, up to an estimated 40 feet from the roofs rake edge to the ground below. Note) Certification and documentation are required for this item.

Date of last update: 30 Mar 2025