336085386
|
1032500
|
2012-08-09
|
BLUE ALDER, COOLIN, ID, 83821
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-09
|
Emphasis |
L: LOGGING
|
Case Closed |
2013-01-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100266 D02 II |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(d)(2)(ii): Each first aid kit did not contain the items listed in Appendix A at all times: (a) Blue Alder: On August 9, 2012, the first aid kit in the Harvester did not contain the minimal acceptable type of first air supplies as required under this paragraph. (b) Blue Alder: On August 9, 2012, the first aid kit in the Forwarder did not contain the minimal acceptable type of first air supplies as required under this paragraph. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100266 D04 |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(d)(4): The employer did not provide and maintain portable fire extinguishers on each machine and vehicle in accordance with the requirements of subpart L of Part 1910. a) Blue Alder: On or about August 9, 2012 and at times prior thereto, the employer did not develop procedures to ensure that fire extinguishers were serviced annually and/or inspected monthly to assure that they would perform as expected in the event of a fire. Note: Abatement certification IS required for this item. |
|
|
336084389
|
1032500
|
2012-08-08
|
ULEEDA POINT, NORDMAN, ID, 83848
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-08
|
Emphasis |
L: LOGGING
|
Case Closed |
2013-06-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100266 D02 I |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(d)(2)(i): The employer did not provide first-aid kits at each work site where trees were being cut, at each active landing, and/or on each employee transport vehicle: (a) Uleeda Point: On August 8, 2012, there was no first aid kit provided where the tree falling was being performed. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100266 H01 IV |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(h)(1)(iv): Employee(s) approached a feller closer than two tree lengths of trees being felled without the feller acknowledging that it was safe to do so: (a) Uleeda Point: On August 8, 2012, employees performing felling operations did not maintain two tree lengths. Note: Abatement certification IS NOT required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100266 I03 III |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(i)(3)(iii): Training content did not consist of the recognition of safety and health hazards associated with the employee's specific work tasks, including the use of measures and work practices to prevent or control those hazards: (a) On August 8, 2012, employees involved in tree felling activities, did not recognize that they were in a hazardous area by not being at least two tree lengths away from the operation. Note: Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100266 D04 |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(d)(4): The employer did not provide and maintain portable fire extinguishers on each machine and vehicle in accordance with the requirements of subpart L of part 1910: (a) Uleeda Point: On August 8, 2012, and at times prior thereto, the employer did not develop procedures to ensure that fire extinguishers were serviced annually and/or inspected monthly to assure that they will perform as expected in the event of a fire. Note: Abatement certification IS required for this item. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100266 F01 III |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(f)(1)(iii): The employer did not assure that operating and maintenance instructions were available either on the machine or in the area where the machine was being operated: (a) Uleeda Point: On August 8, 2012, and times prior thereto, the maintenance and operating manual was missing for the Loader that was in use on the active landing. (b) Uleeda Point: On August 8, 2012, and times prior thereto, the maintenance and operating manual was missing for the Yarder that was in use on the active landing. Note: Abatement certification IS required for this item. |
|
|
336085014
|
1032500
|
2012-08-08
|
HUNTERS ECHOE, COOLIN, ID, 83821
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-08
|
Emphasis |
L: LOGGING
|
Case Closed |
2013-06-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100266 D02 I |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(d)(2)(i): The employer did not provide first-aid kits at each work site where trees were being cut, at each active landing, and/or on each employee transport vehicle: (a) Hunters Echo: On August 8, 2012, the first aid kit was not maintained at the active landing site. Note: Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100266 F01 III |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.266(f)(1)(iii): The employer did not assure that operating and maintenance instructions were available either on the machine or in the area where the machine was being operated: (a) Hunters Echoe: On August 8, 2012, and times prior thereto, the maintenance and operating manual was not maintained in the cab of the Forwarder that was in use on the active landing site. Note: Abatement certification IS required for this item. |
|
|
336085782
|
1032500
|
2012-08-08
|
ULEEDA POINT, NORDMAN, ID, 83848
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-08-08
|
Emphasis |
L: LOGGING
|
Case Closed |
2013-03-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100095 G01 |
Issuance Date |
2013-01-03 |
Abatement Due Date |
2013-03-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
2 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided in this paragraph by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels. a) HC-98 Yarder: On or about August 8, 2012 and at times prior thereto, the employer did not require annual audiograms for an employee exposed to a projected 8 hour time weighted average of 89.4 decibels. b) On or about August 8, 2012 and at times prior thereto, the employer did not required annual audiograms for employees operating chainsaws which would produce an 8 hour time weighted average of greater than 85 decibels. Note: Abatement certification is required for this item. |
|
|
336083787
|
1032500
|
2012-08-07
|
350 PETERSON RD, PRIEST RIVER, ID, 83856
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-07
|
Emphasis |
L: LOGGING
|
Case Closed |
2013-06-17
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100213 A09 |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-29 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219 (a) Shop: On or about August 7, 2012, and at times prior thereto, the Spindle had an unguarded belt and pulley. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Shop: On or about August 7, 2012, and at times prior thereto, the employer had a homemade extension cord in use that was manufactured using Romex. Note: Abatement certification IS requred for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 II |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Shop: On or about August 7, 2012, and at times prior thereto, tables and excess equipment were being stored in front of the electrical breaker panels. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 I |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: (a) Shop: On or about August 7, 2012, and at times prior thereto, exposed conductors were not protected from abrasions. Note: Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 D01 |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked in a conspicuous place in each space to which they related: (a) Shop: On or about August 7, 2012, and at times prior thereto, the load bearing capacity was not posted or otherwise known by workers involved in storage activities. Note: Abatement certification IS required for this item. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100253 B04 III |
Issuance Date |
2013-01-02 |
Abatement Due Date |
2013-01-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: (a) Shop: On or about August 7, 2012 and at times prior thereto, the employer had the oxygen and acetylene cylinders stored together. Note: Abatement certification IS required for this item. |
|
|
303952469
|
1032500
|
2001-08-14
|
OLD SETTLEMENT ROAD, PRIEST RIVER, ID, 83856
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2001-08-14
|
Emphasis |
L: LOGGING, S: AMPUTATIONS, S: LOGGING
|
Case Closed |
2001-08-28
|
|
303952410
|
1032500
|
2001-08-14
|
OLD SETTLEMENT ROAD, PRIEST RIVER, ID, 83856
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2001-08-14
|
Emphasis |
L: LOGGING, S: AMPUTATIONS, S: LOGGING
|
Case Closed |
2002-07-12
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100266 I10 I |
Issuance Date |
2001-08-29 |
Abatement Due Date |
2001-10-03 |
Nr Instances |
7 |
Nr Exposed |
7 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2001-08-29 |
Abatement Due Date |
2001-10-03 |
Nr Instances |
7 |
Nr Exposed |
7 |
Gravity |
01 |
|
|