Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-08
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2019-07-02
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2019-03-07 |
Abatement Due Date |
2019-07-18 |
Current Penalty |
1000.0 |
Initial Penalty |
1932.0 |
Final Order |
2019-03-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Bindery: On or about November 8, 2019 and at times prior thereto; Hans Muller AG, Saddlestitcher, Type 221, NBR 925842. b) Press room: On or about November 8, 2019 and at times prior thereto; Komori Lithrone 28 Offset Press. Note* Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2019-03-07 |
Abatement Due Date |
2019-07-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-03-29 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Bindery: On or about November 8, 2019 and at times prior thereto; Hans Muller AG, Saddlestitcher, Type 221, NBR 925842. b) Press room: On or about November 8, 2019 and at times prior thereto; Komori Lithrone 28. Offset Press. Note* Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100212 A02 |
Issuance Date |
2019-03-07 |
Abatement Due Date |
2019-06-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-03-29 |
Nr Instances |
3 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(2): Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves: Production floor: On or about November 8, 2018, and at times prior thereto; Hans Muller AG, Saddlestitcher, Type 221, NBR 925842, had three cracked guards which could result in slips, trips, or falls if clothes or tools are caught on the guards. Note* Abatement certification IS required for this item. |
|
|