Search icon

MOUNTAIN WEST STUCCO LLC

Company Details

Name: MOUNTAIN WEST STUCCO LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 16 Jan 2018 (7 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 588539
Place of Formation: IDAHO
File Number: 588539
ZIP code: 83687
County: Canyon County
Principal Address: 1604 GARRITY BLVD STE 103 NAMPA, ID 83687
Mailing Address: 532 CALIFORNIA AVE HOMEDALE, ID 83628

Manager

Name Role Address Appointed On
JOSE MARTINEZ MENCHACA Manager 532 CALIFORNIA AVE, HOMEDALE, ID 82392-0271 2021-01-04

Agent

Name Role Address
JOSE MARTINEZ MENCHACA Agent 532 W CALIFORNIA AVE, HOMEDALE, ID 83628-3039

Filing

Filing Name Filing Number Filing date
Annual Report 0006126959 2025-02-24
Annual Report 0005590724 2024-02-07
Annual Report 0005054029 2023-01-05
Annual Report 0004583065 2022-01-27
Annual Report 0004117481 2021-01-04
Annual Report 0003778138 2020-02-10
Annual Report 0003434430 2019-02-21
Initial Filing 0000588539 2018-01-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345463194 1032500 2021-08-05 2015 S EAGLE ROAD, MERIDIAN, ID, 83642
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2021-08-05
Emphasis L: FORKLIFT, L: FALL
Case Closed 2022-04-11

Related Activity

Type Referral
Activity Nr 1795103
Safety Yes
Type Inspection
Activity Nr 1546302
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 2690.7
Initial Penalty 3729.0
Final Order 2022-02-28
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) On August 5, 2021, an employee was using upper deck of tubular weld scaffold that was not fully planked. The planks did not come up to the guardrails exposing the employees to fall hazards of approximately 14 feet high. b) On August 5, 2021, an employee was using an A-frame horse scaffold with a single plank, approximately 3 to 4 feet above the ground. NOTE: Certification of corrective action is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) On August 5, 2021 an employee was using A-frame platform using a plank less than 18 inches wide exposing employee to fall hazards. NOTE: Certification of corrective action is required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On August 5, 2021 an employee was using a tubular welded frame scaffolding missing end guardrails on both ends exposing the employee to fall hazards of approximately 14 feet. NOTE: Certification of corrective action is required for this item.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) On August 5, 2021 an untrained employee was using a tubular welded frame scaffolding exposing the employee to fall hazards of approximately 14 feet. NOTE: Certification of corrective action is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 1700.0
Initial Penalty 2486.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a) On August 5, 2021 an employee was using a tubular welded frame scaffolding with unstable footings on uneven dirt ground and placed next to a hole dug in the ground. NOTE: Certification of corrective action is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified: a) On August 5, 2021 tubular welded frame scaffolding was missing guardrails on both ends of scaffold, was not fully decked/planked, and footings were placed on unstable ground. NOTE: Certification of corrective action is required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work. a) On August 5, 2021, employees had not received adequate training on the appropriate erection of tubular welded scaffolding used for stucco installation. NOTE: Certification of corrective action is required for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 1700.0
Initial Penalty 2486.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On August 5, 2021 an employee was using an unsecured ladder with no grab rail and not extending 3 feet above level when accessing a welded frame scaffold exposing the employee to fall hazards of approximately 14 feet. NOTE: Certification of corrective action is required for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2022-01-31
Abatement Due Date 2022-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-02-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) On August 5, 2021 an employee was not trained in the proper use of ladder usage exposing employee to fall hazards. NOTE: Certification of corrective action is required for this item.

Date of last update: 12 Apr 2025

Sources: Idaho Secretary of State