336934187
|
1032500
|
2012-10-16
|
273 SOUTH 5TH WEST, REXBURG, ID, 83440
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-10-16
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2013-08-16
|
Related Activity
Type |
Referral |
Activity Nr |
619350 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2012-11-01 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2012-12-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: a) Backside of building: On October 16, 2012 an employee performed activities which included installing windows, from a scaffold platform supported by a rough terrain forklift without a fall protection system in place. Note) Abatement certification is NOT required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2012-11-01 |
Abatement Due Date |
2012-11-02 |
Current Penalty |
3000.0 |
Initial Penalty |
4000.0 |
Final Order |
2012-12-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Third floor balcony, front of building: On October 16, 2012 an employee walked from their work area inside the building to an extension ladder at the end of the balcony. A fall protection system was not in place on the open side of the balcony. A Hundred Percenters, Inc. was previously cited for a violation of this Occupational Safety and Health standard which was contained in OSHA inspection number 110131, citation 1, item 1, and was affirmed as a final order on March 16, 2012, with respect to a workplace located at South 5th West and West 5th South, Rexburg ID, 83440. Note) Abatement certification IS required for this item. |
|
|
331101311
|
1032500
|
2011-12-07
|
SOUTH 5TH WEST & WEST 5TH SOUTH, REXBURG, ID, 83440
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-12-07
|
Emphasis |
L: FALL, L: RESCON
|
Case Closed |
2012-04-13
|
Related Activity
Type |
Referral |
Activity Nr |
83917 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
110135 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2012-02-10 |
Current Penalty |
2100.0 |
Initial Penalty |
4200.0 |
Final Order |
2012-03-16 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) West side of structure at the south end, 2nd level; On or about December 7, 2011 and at times prior thereto, an employee was prepping for the installation of a prefabricated exterior wall panel by installing adhesive via a caulking gun at the floor deck edge without a means of fall protection. b) West side of structure, 2nd level; On or about December 7, 2011 and at times prior thereto, two employees carried a completed section of a framed interior wall from one end of the deck to the other without a means of fall protection. c) West side of structure, 2nd level; On or about December 7, 2011 and at times prior thereto, three employees assisting with the installation of a prefabricated exterior wall panel being hoisted by a crane without a means of fall protection. Note: Abatement certification or documentation are NOT required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
2012-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-03-16 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) West side of the 2nd level deck; On or about December 7, 2011 and at times prior thereto, an employee performing faming work including assisting with the placement of prefabricated wall panels via a crane was not wearing a hard hat. Note: Abatement certification is NOT required for this item. |
|
|