Inspection Type |
Unprog Other
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-08-01
|
Emphasis |
L: FORKLIFT, L: FALL, N: HEATNEP
|
Case Closed |
2024-03-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2023-08-31 |
Abatement Due Date |
2023-09-27 |
Current Penalty |
1500.0 |
Initial Penalty |
2679.0 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1):Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut. (a) On or before August 1, 2023, employees were exposed to amputation hazards while using an unguarded table saw, Dewalt Model DWE7491, to cut framing material. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-08-31 |
Current Penalty |
2500.0 |
Initial Penalty |
3349.0 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On August 1, 2023, employees were exposed to falls from 10 to 24 feet to the ground below while performing framing activities. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2023-08-31 |
Current Penalty |
1500.0 |
Initial Penalty |
2009.0 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On August 1st, 2023 framers working on the roof of a new multifamily building were using an A frame ladder to access and exit the roof. The top rail of the ladder was below the landing and employees had to dangle their feet to use the ladder. This condition exposed employees to fall hazards of 10 feet. Abatement Note: Abatement certification is required for this item: See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2023-08-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a)On August 1st, 2023 framers working on the roof of a new multifamily building were using the top step of a stepladder to access and exit the roof. This condition exposed employees to fall hazards of greater than 10 feet. Abatement Note: Abatement certification is required for this item: See enclosed "Certification of Corrective Actions Worksheet." |
|
|