Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-05-16
|
Case Closed |
2020-12-29
|
Related Activity
Type |
Inspection |
Activity Nr |
1316743 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1321109 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-08-14 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
2772.0 |
Initial Penalty |
2772.0 |
Final Order |
2018-11-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system or personal fall arrest systems: a) On or about May 16, 2018, employees performing roofing activities were exposed to a fall hazard while working on a 6 in 12 pitch residential structure without a means of fall protection. Employees were exposed to fall hazards from varied heights between 12-18 feet. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 |
Issuance Date |
2018-08-14 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-11-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a) On or about May 16, 2018 and at times prior thereto, the employer did not provide any, adequate and/or effective fall protection training for employees performing framing work at elevated areas of a residential structure. Employees were exposed to fall hazards from varied heights between 12-18 feet. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2018-08-14 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
2217.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-11-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about May 16, 2018 and at times prior thereto, the employer's ladder extended approximately one foot above the roof landing. Note: Abatement certification IS required this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261053 B20 |
Issuance Date |
2018-08-14 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-11-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(20): When ascending or descending a ladder, the user did not face the ladder. (A) On or about May 16, 2018, employees were exposed to a potential 12 foot fall hazard when observed descending a ladder without holding the rails with both hands. Note: Abatement certification IS required for this item. |
|
|