OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347861494 1032500 2024-11-05 CORNER OF TEMPSTORD WAY AND ESCALANTE DR., EAGLE, ID, 83616
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-11-05
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-12-12
Abatement Due Date 2024-12-24
Current Penalty 1382.5
Initial Penalty 2765.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On November 5th, 2024 employees were exposed to head injuries while working on the ground below framers on the roof. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-12-12
Abatement Due Date 2024-12-18
Current Penalty 0.0
Initial Penalty 2074.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On November 5th, 2024 and times prior, employees using a pneumatic nail gun to install roofing material were not wearing eye protection. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-12-12
Abatement Due Date 2024-12-24
Current Penalty 2419.5
Initial Penalty 4839.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On November 5th, 2024, employees were exposed to falls between 10 and 21 feet to the ground below while performing framing activities. Abatement Note: Abatement certification and documentation is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-12-12
Abatement Due Date 2024-12-18
Current Penalty 2074.0
Initial Penalty 4148.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On November 5th, 2024, employees working on the roof of a new single-family building were using an A-frame lean safe ladder to access and exit the roof. The ladder was positioned below the access point by at least 2.5 feet. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2024-12-12
Abatement Due Date 2024-12-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2025-01-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13):The top or step of a stepladder was used as a step: (a) On November 5, 2024, employees used the top step of an A-frame lean safe ladder to access and exit the roof and work area. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."