Search icon

COMPLETE CONSTRUCTION, INC.

Company Details

Name: COMPLETE CONSTRUCTION, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Active-Good Standing
Date of registration: 06 Nov 2008 (16 years ago)
Financial Date End: 30 Nov 2025
Entity Number: 546608
Place of Formation: IDAHO
File Number: 546608
Mailing Address: PO BOX 2615 TWIN FALLS, ID 83303-2615

Agent

Name Role Address
Jeremy Black Agent 1646 ELDREDGE AVENUE, TWIN FALLS, ID 83301

President

Name Role Address Appointed On
Jeremy Black President PO BOX 2615, TWIN FALLS, ID 83301 2023-03-30

Vice President

Name Role Address Appointed On Resigned On
Jeremy Black Vice President PO BOX 2615, TWIN FALLS, ID 83301 2020-10-13 2023-03-30

Filing

Filing Name Filing Number Filing date
Annual Report 0005931550 2024-10-07
Annual Report 0005444947 2023-10-19
Annual Report Amendment 0005171365 2023-03-30
Annual Report 0004966087 2022-11-01
Annual Report 0004440401 2021-10-06
Annual Report 0004030636 2020-10-13
Change of Registered Office/Agent/Both (by Entity) 0003730812 2020-01-06
Articles of Amendment 0003730824 2020-01-06
Annual Report 0003640707 2019-10-03
Annual Report 0003341676 2018-11-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342238987 1032500 2017-04-07 1855 CANYON CREST DRIVE, TWIN FALLS, ID, 83301
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-04-07
Case Closed 2017-05-24

Related Activity

Type Referral
Activity Nr 1200586
Safety Yes
Type Inspection
Activity Nr 1224057
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2017-04-11
Abatement Due Date 2017-05-05
Current Penalty 1616.0
Initial Penalty 3232.0
Final Order 2017-05-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical agents: (a) Putters Mini Golf, Twin Falls, ID: On or about April 7, 2017, and at times prior, employees were performing roofing activities with pneumatic nail gun without wearing impact resistant eye protection. Note: Abatement certification IS required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2017-04-11
Current Penalty 2693.5
Initial Penalty 5387.0
Final Order 2017-05-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level were not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Job site: On or about April 7, 2017, the employer did not ensure employees were protected from fall hazards while performing roofing activities. Employees were exposed to fall hazards ranging from 18-28 feet on this 4 in 12 pitch roof structure. Note) Corrected during inspection
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260502 D17
Issuance Date 2017-04-11
Abatement Due Date 2017-05-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: (a) Job site: On or about April 7, 2017, and at times prior thereto, an employee was observed with his harness improperly adjusted with the D-ring on his lower back. Note: Abatement certification IS required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260503 C03
Issuance Date 2017-04-11
Abatement Due Date 2017-05-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill. a) On or about April 7, 2017, and at times prior thereto, an employee wearing a personal fall arrest system did not acknowledge the requirement to anchor off taking the appropriate actions to minimize and/or eliminate these hazards. b) On or about April 7, 2017, and at times prior thereto, an employee did not recognize the importance of properly donning his harness so the D-ring is located at the center of the wearer's back. Note) Abatement certification IS required for this item.
342201027 1032500 2017-03-23 161 MAIN STREET, TWIN FALLS, ID, 83301
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-03-23
Case Closed 2017-05-24

Related Activity

Type Referral
Activity Nr 1195597
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2017-04-11
Abatement Due Date 2017-04-17
Current Penalty 2693.5
Initial Penalty 5387.0
Final Order 2017-05-02
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) Commercial jobsite: On March 23, 2017 and at times prior thereto employees performed roofing activities on a low sloped roof of a commercial building. No fall protection system was in place along the side walls or along the open back, exposing employees to a fall hazard up to approximately 32 feet to the street below. Note) Certification of corrective action is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-04-11
Abatement Due Date 2017-04-17
Current Penalty 1616.0
Initial Penalty 3232.0
Final Order 2017-05-02
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a) Commercial jobsite: On March 23, 2017 and at times prior thereto an extension ladder was used for access to the roof area. The ladder did not extend at least 3 feet above the side wall nor was it secured to the building. Note) Certification of corrective action is required for this item.
311581110 1032500 2009-02-19 TIMBERLAKE AFFORDABLE HOUSING, KIMBERLY RD, TWIN FALLS, ID, 83303
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2009-02-19
Emphasis L: FALL, S: RESIDENTIAL CONSTR, L: RESCON, S: FALL FROM HEIGHT
Case Closed 2009-02-20
311580229 1032500 2008-12-29 187 MEADOW VIEW LANE, TWIN FALLS, ID, 83301
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2008-12-29
Emphasis S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT, L: RESCON, L: FALL
Case Closed 2009-01-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2009-01-08
Abatement Due Date 2009-01-13
Current Penalty 225.0
Initial Penalty 225.0
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 01

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
8541497000 2020-04-08 1087 PPP 1646 ELDRIDGE AVE, TWIN FALLS, ID, 83301-7817
Loan Status Date 2022-03-09
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 170100
Loan Approval Amount (current) 170100
Undisbursed Amount 0
Franchise Name -
Lender Location ID 96211
Servicing Lender Name Idaho Central CU
Servicing Lender Address 4400 Central Way, CHUBBUCK, ID, 83202-5096
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address TWIN FALLS, TWIN FALLS, ID, 83301-7817
Project Congressional District ID-02
Number of Employees 13
NAICS code 236115
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 96211
Originating Lender Name Idaho Central CU
Originating Lender Address CHUBBUCK, ID
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 171745.08
Forgiveness Paid Date 2021-03-31

Date of last update: 10 Apr 2025

Sources: Idaho Secretary of State