Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-06-26
|
Emphasis |
L: FALL
|
Case Closed |
2020-07-10
|
Related Activity
Type |
Referral |
Activity Nr |
1469919 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2019-07-08 |
Abatement Due Date |
2019-08-01 |
Current Penalty |
852.5 |
Initial Penalty |
1705.0 |
Final Order |
2019-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) On or about June 26, 2019, and at times prior, employees were exposed to eye hazards from flying objects while use pneumatic nail guns without approved eye protection. Note: Abatement certification is required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2019-07-08 |
Abatement Due Date |
2019-08-01 |
Current Penalty |
1705.0 |
Initial Penalty |
3410.0 |
Final Order |
2019-07-29 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). a) On or about June 26, 2019, and at times prior, employees were exposed to fall hazards of 15 feet above the ground while working on a 10 inch wide scaffold plank from homemade scaffolding. Note: Abatement certification is required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-07-08 |
Abatement Due Date |
2019-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-29 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about June 26, 2019, and at times prior, employees were exposed to fall hazards without fall protection while working on the roof. Note: Abatement certification is required for this item. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2019-07-08 |
Abatement Due Date |
2019-08-01 |
Current Penalty |
852.5 |
Initial Penalty |
1705.0 |
Final Order |
2019-07-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) On or about June 26, 2019, and at times prior, employees were exposed to fall hazards when climbing wood-framed walls an additional 2.2 feet beyond the top level of the 6 foot ladder being used to access trusses to install sheathing. Note: Abatement certification is required for this item. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2019-07-08 |
Abatement Due Date |
2019-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) On or about June 26, 2019, and at times prior, employees were exposed to fall hazards from stepping on top level of the 6 foot Werner ladder being used to access trusses to install sheathing. Note: Abatement certification is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260404 F07 IV |
Issuance Date |
2019-07-08 |
Abatement Due Date |
2019-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(7)(iv): Equipment connected by cord and plug. Under any of the conditions described in paragraphs (f)(7)(iv)(A) through (f)(7)(iv)(C) of this section, exposed noncurrent-carrying metal parts of cord- and plug-connected equipment which may become energized shall be grounded. (a) On or about June 26, 2019, and at times prior, employees were cutting sheathing using Skilsaw's that had the grounding prongs removed. Note: Abatement certification is required. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2019-07-08 |
Abatement Due Date |
2019-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) On or about June 26, 2019, and at times prior, and employee was cutting sheathing using a Makita reciprocating saw that had a cord pulled away from the plug. Note: Abatement certification is required. |
|
|