Search icon

Ark Commercial Roofing, Inc.

Company Details

Name: Ark Commercial Roofing, Inc.
Jurisdiction: Idaho
Legal type: Foreign Business Corporation
Status: Active-Good Standing
Date of registration: 05 Oct 2023 (a year ago)
Financial Date End: 31 Oct 2025
Entity Number: 5431058
Place of Formation: WASHINGTON
File Number: 901475
Principal Address: 11505 E TRENT AVE SPOKANE VALLEY, WA 99206
Mailing Address: 11505 E TRENT AVE SPOKANE VALLEY, WA 99206-4633

Agent

Name Role Address
ANNUAL $46.00- BLAKE'S REGISTERED AGENTS LLC Agent 19593 MADISON RD, NAMPA, ID 83687

President

Name Role Address Appointed On
Elaine Wilson President 11505 E TRENT AVE, SPOKANE VALLEY, WA 99206-4633 2024-09-04

Filing

Filing Name Filing Number Filing date
Annual Report 0005881977 2024-09-04
Initial Filing 0005431058 2023-10-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346115785 1032500 2022-08-01 COEUR D' ALENE TOWNEPLACE SUITES HOTEL PROJECT 1381 N. NORTHWOOD CENTER, COEUR D ALENE, ID, 83814
Inspection Type Prog Other
Scope Complete
Safety/Health Safety
Close Conference 2022-08-01
Emphasis N: CTARGET
Case Closed 2023-03-07

Related Activity

Type Inspection
Activity Nr 1611576
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2023-01-18
Current Penalty 2009.0
Initial Penalty 2009.0
Final Order 2023-02-15
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2):Installation and use. Listed, labeled, or certified equipment were not installed and used in accordance with instructions included in the listing, labeling, or certification. a). Coeur D' Alene Towneplace 1381 N. Northwood Center Court Couer D' Alene, ID. 83814 - Roof - Multiway Surge Protective Device - relocatable power tap (RPT) Model No: FS-071A3 Type 3 125V-15A 60 Hz - On or about August 1, 2022 and at times prior thereto, employees were exposed to an electrical shock of 110VAC in that the RPT was energizing two separate extension cords that were connected to DeWalt Power Drills for use to install roofing material.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260404 B01 III C
Issuance Date 2023-01-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-02-15
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective were used until repaired. a). Coeur D' Alene Towneplace Construction Project - 1381 N. Northwood Center Court Coeur D' Alene, ID. 83814 - Roof - On or about August 1, 2022 and at times prior thereto, employees were exposed to an electrical shock of 110VAC in that the grounding pin on the extension cord were removed/missing. The RPT and extension cord was energizing a DeWalt Power Drill for use to install roofing material.
311579643 1032500 2008-12-03 2903 RAMSEY RD., COEUR D'ALENE, ID, 83815
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2008-12-04
Emphasis S: FALL FROM HEIGHT, S: COMMERCIAL CONSTR, L: FALL
Case Closed 2009-02-13

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19260151 A03
Issuance Date 2008-12-29
Abatement Due Date 2009-01-16
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 14
Gravity 02
Citation ID 01001B
Citaton Type Other
Standard Cited 19260153 O
Issuance Date 2008-12-29
Abatement Due Date 2009-01-02
Current Penalty 600.0
Nr Instances 1
Nr Exposed 14
Gravity 02
Citation ID 01001C
Citaton Type Other
Standard Cited 19101200 F05 I
Issuance Date 2008-12-29
Abatement Due Date 2009-01-16
Nr Instances 1
Nr Exposed 14
Gravity 02
Citation ID 01001D
Citaton Type Other
Standard Cited 19101200 F05 II
Issuance Date 2008-12-29
Abatement Due Date 2009-01-16
Nr Instances 1
Nr Exposed 14
Gravity 02

Date of last update: 03 Mar 2025