344470638
|
1032500
|
2019-11-20
|
283 FILLMORE ST, TWIN FALLS, ID, 83301
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-11-20
|
Emphasis |
L: FALL
|
Case Closed |
2021-01-08
|
Related Activity
Type |
Complaint |
Activity Nr |
1520851 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2019-12-09 |
Abatement Due Date |
2020-01-06 |
Current Penalty |
3500.0 |
Initial Penalty |
5304.0 |
Final Order |
2020-01-07 |
Nr Instances |
2 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: a) On or about November 20, 2019 and at times prior thereto; 12 employees removing asphalt and wood shingles from a 10:12 pitch roof were not protected from 10-18 foot falls. b) On or about November 20, 2019 and at times prior thereto; 12 employees removing shingles from a 10:12 pitch roof accessed an extension ladder that was not extended three feet to the landing surface, or secured to prevent the ladder from shifting in gravel landscaping rock. Note: Abatement certification and documentation are required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-12-09 |
Abatement Due Date |
2020-01-06 |
Current Penalty |
3500.0 |
Initial Penalty |
5304.0 |
Final Order |
2020-01-07 |
Nr Instances |
1 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about November 21, 2019 and at times prior thereto; 12 workers were exposed to 10-18 foot fall hazards while pulling asphalt and wood shingles from a one story, 10:12 pitch residential roof. Note: Abatement certification and documentation are required for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2019-12-09 |
Abatement Due Date |
2020-01-06 |
Current Penalty |
3000.0 |
Initial Penalty |
4546.0 |
Final Order |
2020-01-07 |
Nr Instances |
3 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about November 21, 2019 and at times prior thereto; 12 roofers working from a one story, 10:12 pitch roof accessed an extension ladder that was placed in landscaping rock, but was extended less than three feet. Note: Abatement certification is required for this item. |
|
|
343174686
|
1032500
|
2018-05-15
|
CORNER OF FILER ST. AND FILLMORE ST., TWIN FALLS, ID, 83301
|
|
Inspection Type |
Complaint
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2018-05-15
|
Case Closed |
2018-05-22
|
Related Activity
Type |
Complaint |
Activity Nr |
1337090 |
Safety |
Yes |
|
|
330293747
|
1032500
|
2011-05-03
|
444 2ND AVE N, TWIN FALLS, ID, 83301
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-05-03
|
Emphasis |
L: FALL
|
Case Closed |
2012-05-04
|
Related Activity
Type |
Referral |
Activity Nr |
20666 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2011-09-07 |
Abatement Due Date |
2011-09-08 |
Current Penalty |
990.0 |
Initial Penalty |
1980.0 |
Final Order |
2011-09-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities six (6) feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor was an alternative fall protection measure provided:\\\\\\\\r\\\\\\\\n\\\\\\\\r\\\\\\\\nOn 05/03/11 and at times prior thereto, employees were exposed to a fall hazard while performing a re-roof on an 8 in 12 slope roof of a residential structure with a ground to eave height of 9.4 to 12.4 feet. No means of fall protection was utilized.\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\n\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\n\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\n\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\nNote: Effective September 16, 2011 conventional methods for fall protection, per 29 CFR 1926.501(b)(13) shall be used. The alternative methods for fall protection in residential construction as described in STD 03-00-001 will no longer be acceptable. \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\n\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\r\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\n |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 A01 |
Issuance Date |
2011-09-07 |
Abatement Due Date |
2011-09-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-09-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program did not enable each employee to recognize the hazards of falling and did not train each employee in the procedures to be followed in order to minimize these hazards. a) On 05/03/11 and at times prior thereto, employees were not trained to recognize fall hazards before performing re-roof activities on an 8 in 12 slope roof of a residential structure with a ground to eave height of 9.4 to 12.4 feet. No means of fall protection was utilized. Bottom layer was cedar shake. Note: Effective September 16, 2011 conventional methods for fall protection, per 29 CFR 1926.501(b)(13) shall be used. The alternative methods for fall protection in residential construction as described in STD 03-00-001 will no longer be acceptable. Note: Abatement certification IS required for this item |
|
|