Name: | EJ Construction and Framing LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 15 Aug 2023 (2 years ago) |
Financial Date End: | 31 Aug 2025 |
Entity Number: | 5363582 |
Place of Formation: | IDAHO |
File Number: | 893485 |
ZIP code: | 83616 |
County: | Ada County |
Principal Address: | 3520 E CHINDEN BOULEVARD EAGLE, ID 83616 |
Mailing Address: | 3520 E CHINDEN BLVD EAGLE, ID 83616 |
Name | Role | Address |
---|---|---|
VALLE ACCOUNTING, LLC | Agent | 5680 E FRANKLIN RD, SUITE 225, NAMPA, ID 83687 |
Name | Role | Address | Appointed On |
---|---|---|---|
Diana Duran Gonzalez | Member | 3520 E CHINDEN BLVD, EAGLE, ID 83616 | 2024-08-06 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005849783 | 2024-08-06 |
Initial Filing | 0005363582 | 2023-08-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347523102 | 1032500 | 2024-05-31 | 6291 W RIVA CAPRI STREET, MERIDIAN, ID, 83646 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2171969 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-08-05 |
Abatement Due Date | 2024-08-15 |
Current Penalty | 2765.0 |
Initial Penalty | 2765.0 |
Final Order | 2024-09-04 |
Nr Instances | 1 |
Nr Exposed | 7 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On May 31, 2024, employees performing framing activities without fall protection were exposed to falls of approximately 12 feet. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2024-08-05 |
Abatement Due Date | 2024-08-09 |
Current Penalty | 2074.0 |
Initial Penalty | 2074.0 |
Final Order | 2024-09-04 |
Nr Instances | 1 |
Nr Exposed | 6 |
Related Event Code (REC) | Referral |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) On May 31, 2024, employees performing framing activities used the top step of a closed 8-foot A-Frame ladder to access the second story floor. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2024-08-05 |
Abatement Due Date | 2024-08-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-09-04 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: (a) On May 31, 2024, employees performing framing activities used the top step of a closed 8-foot A-Frame ladder to access the second story floor. |
Date of last update: 27 Mar 2025
Sources: Idaho Secretary of State