Search icon

ECM CONSTRUCTION, LLC

Company Details

Name: ECM CONSTRUCTION, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 19 Jan 2017 (8 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 536265
Place of Formation: IDAHO
File Number: 536265
ZIP code: 83687
County: Canyon County
Principal Address: 104 S GREENSCAPE WAY NAMPA, ID 83687
Mailing Address: EDGAR CAMACHO 1226 LONE STAR RD NAMPA, ID 83651-7610

Agent

Name Role Address
EDGAR CAMACHO Agent 1226 LONE STAR RD, NAMPA, ID 83651

Manager

Name Role Address Appointed On
Edgar Camacho Marquez Manager 1226 LONE STAR RD, NAMPA, ID 83651-7610 2022-10-19

Filing

Filing Name Filing Number Filing date
Annual Report Amendment 0006086605 2025-01-31
Annual Report 0006003010 2024-12-03
Annual Report 0005495970 2023-12-04
Annual Report 0005010992 2022-12-05
Application for Reinstatement 0004956914 2022-10-19
Dissolution/Revocation - Administrative 0004240158 2021-04-08
Annual Report 0003698120 2019-12-03
Annual Report 0003447577 2019-03-11
Application for Reinstatement 0003152721 2018-05-16
Application for Reinstatement 0000925871 2018-05-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345845408 1032500 2022-03-18 LOT 15-4 HAZEL GROUSE WAY, BOISE, ID, 83714
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-03-18
Emphasis L: FALL
Case Closed 2023-04-17

Related Activity

Type Referral
Activity Nr 1877133
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 D16 III
Issuance Date 2022-03-31
Abatement Due Date 2022-04-06
Current Penalty 3276.0
Initial Penalty 2735.0
Final Order 2022-09-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16)(iii):Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or about March 18, 2022; an employee performing framing activities was not protected from falls due to the lenght of the rope being used. The rope used was longer than the fall distance of approximately 12 feet. Note - Abatement certification is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-03-31
Abatement Due Date 2022-04-12
Current Penalty 0.0
Initial Penalty 5469.0
Final Order 2022-09-12
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 18, 2022; employees were exposed to falls of approximately 12 feet while performing framing activities without fall protection. ECM Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1310168, citation number 1, item number 2a, and was affirmed as a final order on 05/23/2018, with respect to a workplace located at 9555 W Ringle Creek Street, Star, ID 83669. Note - Abatement certification and documentation are required for this item.
343101689 1032500 2018-04-20 9555 W RINGLE CREEK STREET, STAR, ID, 83669
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-04-20
Case Closed 2020-07-10

Related Activity

Type Referral
Activity Nr 1330190
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2018-04-30
Abatement Due Date 2018-05-24
Current Penalty 1663.0
Initial Penalty 3326.0
Final Order 2018-05-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) On or about April 20, 2018 and at times prior thereto employees were exposed to struck by hazards while working below other employees who were using pneumatic nail guns and hand tools, and while lifting sheets of exterior roof sheathing over their head to the above employees, where no hard hats were worn. NOTE-Abatement certification is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-04-30
Abatement Due Date 2018-05-24
Current Penalty 1940.0
Initial Penalty 3880.0
Final Order 2018-05-23
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about April 20, 2018 and at times prior thereto employees were nailing exterior sheathing to a roof, exposed to fall hazards from between 13 to 19 feet, where no fall protection was provided or used. b) On or about April 20, 2018 and at times prior thereto employees were working on the second floor exposed to 10 foot fall hazards at three unguarded wall openings, where no fall protection was provided or used. NOTE-Abatement certification and documentation are required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2018-04-30
Abatement Due Date 2018-05-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-05-23
Nr Instances 2
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about April 20, 2018 and at times prior thereto employees were exposed to fall hazards of 10, 13, and 19 feet to the ground below, where untrained employees were unable to recognize or avoid the hazards, or to wear and use personal fall arrest systems. NOTE-Abatement certification is required for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2018-04-30
Abatement Due Date 2018-05-24
Current Penalty 1663.0
Initial Penalty 3326.0
Final Order 2018-05-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about April 20, 2018 and at times prior thereto employees were working from a 10 foot ladder which was folded, and leaning against the building. NOTE-Abatement certification is required for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2018-04-30
Abatement Due Date 2018-05-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-05-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about April 20, 2018 and at times prior thereto employees were using the top and top step of an eight foot folding ladder to access a 10 foot high second floor. NOTE-Abatement certification is required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
1971537803 2020-05-22 1087 PPP 275 S Paradise Ave, Middleton, ID, 83644
Loan Status Date 2021-02-03
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 39100
Loan Approval Amount (current) 39100
Undisbursed Amount 0
Franchise Name -
Lender Location ID 96211
Servicing Lender Name Idaho Central CU
Servicing Lender Address 4400 Central Way, CHUBBUCK, ID, 83202-5096
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Middleton, CANYON, ID, 83644-0001
Project Congressional District ID-01
Number of Employees 6
NAICS code 238130
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 96211
Originating Lender Name Idaho Central CU
Originating Lender Address CHUBBUCK, ID
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 39353.88
Forgiveness Paid Date 2021-01-20

Date of last update: 10 Apr 2025

Sources: Idaho Secretary of State