Search icon

PRESTIGE ROOFING LLC

Company Details

Name: PRESTIGE ROOFING LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 28 Dec 2016 (8 years ago)
Financial Date End: 31 Dec 2019
Date dissolved: 10 Mar 2020
Entity Number: 533177
Place of Formation: IDAHO
File Number: 533177
ZIP code: 83301
County: Twin Falls County
Principal Address: 2331 LONGBOW DRIVE TWIN FALLS, ID 83301
Mailing Address: 2331 LONGBOW DR TWIN FALLS, ID 83301-4443

Agent

Name Role Address
JESSE D HARRAL Agent 2331 LONGBOW DR, TWIN FALLS, ID 83301

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0003808511 2020-03-10
Annual Report 0003362251 2018-12-05
Annual Report 0003145713 2017-11-02
Initial Filing 0000533177 2016-12-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342812625 1032500 2017-12-01 761 MAIN AVE E, HOLLISTER, ID, 83301
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-12-01
Case Closed 2018-08-23

Related Activity

Type Complaint
Activity Nr 1288890
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260416 A01
Issuance Date 2018-01-26
Abatement Due Date 2018-02-22
Current Penalty 1940.0
Initial Penalty 3880.0
Final Order 2018-02-07
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: (a) Top of structure: On December 1, 2017, employees engaged in roof ing activities were making contact with and working in the proximity of an energized 120/240 single-phase power line. Note: Abatement certification and documentation are required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2018-01-26
Abatement Due Date 2018-02-22
Current Penalty 1413.5
Initial Penalty 2827.0
Final Order 2018-02-07
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems or safety monitoring system. (a) Top of the roof: On December 1, 2017 employees were exposed to 8.9 ft falls onto pavement. (b) Top of refuse dumpster: On December 1, 2017 employees were exposed to 7.2 ft falls onto pavement. Note: Abatement certification is required for this item
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-01-26
Abatement Due Date 2018-02-22
Current Penalty 942.5
Initial Penalty 1885.0
Final Order 2018-02-07
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Back of building: On December 1, 2018 the ladder used by employees to access and exit the roof extended approximately 18 inches above the upper landing level. Note: Abatement certification is required for this item.