Name: | ALPHA MASONRY, INC. |
Jurisdiction: | Idaho |
Legal type: | General Business Corporation (D) |
Status: | Active-Good Standing |
Date of registration: | 15 May 2007 (18 years ago) |
Financial Date End: | 31 May 2025 |
Entity Number: | 524359 |
Place of Formation: | IDAHO |
File Number: | 524359 |
ZIP code: | 83617 |
County: | Gem County |
Mailing Address: | TARA EKSTROM 2671 W SUCCESS WAY EMMETT, ID 83617-5101 |
Name | Role | Address |
---|---|---|
DARRELL COLEMAN | Agent | 2671 W SUCCESS WAY, EMMETT, ID 83617 |
Name | Role | Address | Appointed On |
---|---|---|---|
Tara L Ekstrom | Secretary | 2671 W SUCCESS WAY, EMMETT, ID 83617 | 2021-04-14 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005779840 | 2024-06-13 |
Annual Report | 0005200328 | 2023-04-13 |
Annual Report | 0004686170 | 2022-04-04 |
Annual Report | 0004247407 | 2021-04-14 |
Annual Report | 0003898625 | 2020-06-04 |
Annual Report | 0003491871 | 2019-04-24 |
Annual Report | 0003124877 | 2018-06-25 |
Annual Report | 0003124875 | 2017-03-27 |
Annual Report | 0003124874 | 2016-03-20 |
Annual Report | 0003124873 | 2015-04-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344060298 | 1032500 | 2019-06-05 | 623 UNIVERSITY PLACE, NAMPA, ID, 83686 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1406283 |
Health | Yes |
Type | Complaint |
Activity Nr | 1462352 |
Health | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19261153 C01 |
Issuance Date | 2019-07-23 |
Abatement Due Date | 2019-08-16 |
Current Penalty | 1932.0 |
Initial Penalty | 1932.0 |
Final Order | 2019-08-19 |
Nr Instances | 2 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, and employer did not assess or limit the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section. a) Northwest Nazarene University Student Commons Building Project: On or about June 6, 2019 and at times prior thereto; Husqavarna K760 Saw did not have a manufacturer approved water attachment. Note* Abatement certification IS required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19261153 C02 II |
Issuance Date | 2019-07-23 |
Abatement Due Date | 2019-08-16 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-08-19 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(c)(2)(ii): Water was not applied at flow rates sufficient to minimize release of visible dust for tasks performed using wet methods: a) Northwest Nazarene University Student Commons Building Project: On or about June 6, 2019 and at times prior thereto; Masons and Hoddies are hand chipping limestone and cutting limestone and cast stone trim pieces using a Husqvarna K760 had held gas power cutter with wet methods. Clogging of the water hose affected water pressure, which created visible dust in the work area. Note* Abatement certification IS required for this item. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19261153 G01 |
Issuance Date | 2019-07-23 |
Abatement Due Date | 2019-09-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-08-19 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) Northwest Nazarene University Student Commons Building Project: On or about June 6, 2019 and at times prior thereto; employer did not have a written Exposure Control Plan; Masons and Hoddies are hand chipping limestone and cutting limestone and cast stone trim pieces using a Husqvarna K760 with wet methods. Note* Abatement certification IS required for this item. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5054828009 | 2020-06-26 | 1087 | PPP | 1399 WEST GANDER DR, MERIDIAN, ID, 83642-6143 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2459871 | Intrastate Non-Hazmat | 2023-01-13 | 1 | 2022 | 1 | 1 | Exempt For Hire | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 10 Apr 2025
Sources: Idaho Secretary of State