Search icon

J & N ROOFING, LLC

Company Details

Name: J & N ROOFING, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 06 Sep 2016 (9 years ago)
Financial Date End: 30 Sep 2025
Entity Number: 519630
Place of Formation: IDAHO
File Number: 519630
ZIP code: 83686
County: Canyon County
Principal Address: APT 102 1169 S SHARONS CT NAMPA, ID 83686-6058
Mailing Address: 2123 S ELDER ST NAMPA, ID 83686-7259

Agent

Name Role Address
VALLE ACCOUNTING, LLC Agent 5680 E FRANKLIN RD, SUITE 225, NAMPA, ID 83687

Member

Name Role Address Appointed On Resigned On
Hector Jimenez Member 2123 S ELDER ST, NAMPA, ID 83686 2020-08-12 2023-01-05
Victor Jimenez Member 2123 S ELDER ST, NAMPA, ID 83686 2024-08-01 No data
Hector Jimenez Member 2123 S ELDER ST, NAMPA, ID 83686 2024-08-01 No data

Filing

Filing Name Filing Number Filing date
Annual Report 0005835587 2024-08-01
Application for Reinstatement 0005548965 2024-01-08
Dissolution/Revocation - Administrative 0005514239 2023-12-16
Application for Reinstatement 0005053932 2023-01-05
Dissolution/Revocation - Administrative 0004539704 2021-12-24
Annual Report 0003970464 2020-08-12
Application for Reinstatement 0003645483 2019-10-09
Statement of Change of Business Mailing Address 0003645477 2019-10-09
Dissolution/Revocation - Administrative 0003393248 2019-01-10
Annual Report 0003113531 2017-11-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342990165 1032500 2018-03-02 575 WHITE CLOUD DRIVE, BOISE, ID, 83709
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2018-03-02
Case Closed 2020-08-31

Related Activity

Type Complaint
Activity Nr 1314770
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2018-05-03
Abatement Due Date 2018-05-30
Current Penalty 1400.0
Initial Penalty 2772.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) On or about March 2, 2018 and at times prior thereto employees were cleaning up roofing debris on the ground, and were not wearing hard hats, working directly below employees on the roof. NOTE-Abatement certification is required for this item.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2018-05-03
Abatement Due Date 2018-05-30
Current Penalty 4600.0
Initial Penalty 6652.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 2, 2018 and at times prior thereto employees were removing shingles and tar paper from a roof, exposed to fall hazards from between 8 to 13 feet, where no fall protection was used. NOTE-Abatement certification and documentation are required for this item. THE COMPANY, J & N ROOFING, LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(b)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1225601, CITATION NUMBER 1, ITEM 2a, ISSUED ON APRIL 25th, 2017 WITH A FINAL ORDER DATE OF MAY 16th, 2017, WITH RESPECT TO A WORKPLACE LOCATED AT 393 S FARM HILL AVENUE, MERIDIAN, ID.
Citation ID 03001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2018-05-03
Abatement Due Date 2018-05-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-08
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about March 2, 2018 and at times prior thereto the employer did not verify that employees were trained in accordance with 29 CFR 1926.503(a) by preparing or maintaining a written certification of fall protection training. NOTE-Abatement certification is required for this item.
342256013 1032500 2017-04-17 393 S HILL FARM AVENUE, MERIDIAN, ID, 83642
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-04-17
Case Closed 2019-02-22

Related Activity

Type Referral
Activity Nr 1202678
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260028 A
Issuance Date 2017-04-25
Abatement Due Date 2017-05-19
Current Penalty 815.0
Initial Penalty 1630.0
Final Order 2017-05-16
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) On April 17, 2017 and at times prior thereto employees performed roofing activities which required the use of a nail gun, without eye protection. Note) Certification of corrective action is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-04-25
Abatement Due Date 2017-05-19
Current Penalty 1086.5
Initial Penalty 2173.0
Final Order 2017-05-16
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about April 17, 2017, employees performing roofing activities were exposed to an approximate 10 foot fall hazard while working on a 10 in 12 pitch on a residential structure without a means of falll protection. Note: Abatement certification IS required for these items.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2017-04-25
Abatement Due Date 2017-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a) On or about April 17, 2017 and at times prior thereto, the employer did not provide any, adequate and/or effective fall protection training for two employees performing roofing work at elevated areas of a residential structure. Note: Abatement certification IS required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-04-25
Abatement Due Date 2017-05-19
Current Penalty 815.0
Initial Penalty 1630.0
Final Order 2017-05-16
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about April 17, 2017, employees involved in roofing activities utilized an extension ladder to access a steep 10 in 12 pitch roof that did not have any extension over the roof edge. . Note: Abatement certification IS required for this item

Date of last update: 10 Apr 2025

Sources: Idaho Secretary of State