Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-11-21
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2014-06-27
|
Related Activity
Type |
Complaint |
Activity Nr |
862217 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
1200.0 |
Initial Penalty |
2400.0 |
Final Order |
2014-02-03 |
Nr Instances |
3 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On November 21, 2013, and at times prior thereto, the employer had not developed, implemented and maintained written lockout/tagout procedures for employees operating and performing servicing and maintenance on equiipmeint including, but not limited to: the SCMI Topset planer/moulder; the circle saw located in the north east corner of the warehouse, and the wire brush machines located on the east side of the warehouse NOTE: Abatement certification IS required for this item |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) In running pinch points were not guarded from contact including, but not limited to, the infeed rollers for the wire brush machine. Note: Abatement certification IS required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) Two chain and sprockets were not guarded on the infeed side of the wire brush machine. Note: Abatement certification is required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-02-03 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Terratek 10" mitre saw that was not anchored to the work table and moved when used. b) Hitachi C12RSH mitre saw that was not anchored to the work table and moved when used. NOTE: Abatement certification IS required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100213 R04 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation of a miter / chop saw: a) The lower blade guard for the table top Terrateck 10" miter saw was stuck and did not return to cover the lower portion of the blade when the saw was released to the up position. Note: Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition. a) Paint Shop: On November 21, 2013, and at times prior thereto, a large number of 6-gallon containers of wood stain were left on the floor in this area. NOTE: Abatement certification IS required for this item. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) A written respiratory protection program was not in place for workers including those using tight fitting cartridge respirators in the paint shop. Note: Abatement certification IS required for this item. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100176 B |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
1 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) Delivery Yard: On November 21, 2013, and at times prior thereto, wood bundles were not stored in a stable configuration and were occasionally climbed on by workers in order to obtain materials. NOTE: Abatement certification IS required for this item. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 |
Issuance Date |
2014-01-14 |
Abatement Due Date |
2014-01-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-03 |
Nr Instances |
2 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Warehouse, east wall: On November 21, 2013, and at times prior thereto, an electrical circuit breaker panel was blocked and not accessible. b) Warehouse, south wall: On November 21, 2013, and at times prior thereto, an electrical circuit breaker panel was blocked by buckets of wood staining compound and not accessible. NOTE: Abatement certification IS required for this item. |
|
|