CAGE number | Status | Type | Established | CAGE Update Date | CAGE Expiration | SAM Expiration | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6JMY4 | Obsolete | Non-Manufacturer | 2011-09-22 | 2022-07-11 | 2022-07-10 | No data | |||||||||||||||
|
POC | KATHY KUBIAK |
Phone | +1 208-263-8700 |
Fax | +1 208-265-9605 |
Address | 1603 BALDY PARK DRIVE, SANDPOINT, ID, 83864, UNITED STATES |
Ownership of Offeror Information
Highest Level Owner | Information not Available |
---|
Immediate Level Owner | Information not Available |
---|
List of Offerors (0) | Information not Available |
---|
Name | Role | Address |
---|---|---|
DARCY SHROPSHIRE, CPA | Agent | 414 CREEKSIDE LANE, SANDPOINT, ID 83864 |
Name | Role | Address | Appointed On |
---|---|---|---|
Darcy McDougall | Treasurer | 414 CREEKSIDE LANE, SANDPOINT, ID 83864 | 2020-11-05 |
Name | Role | Address | Appointed On |
---|---|---|---|
Randy McDougall | President | 414 CREEKSIDE LANE, SANDPOINT, ID 83864 | 2023-11-10 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005475428 | 2023-11-10 |
Statement of Change of Business Mailing Address | 0005093438 | 2023-02-03 |
Annual Report | 0005093417 | 2023-02-03 |
Annual Report | 0004486128 | 2021-11-04 |
Annual Report | 0004059910 | 2020-11-05 |
Annual Report | 0003688709 | 2019-12-01 |
Annual Report | 0003438388 | 2019-02-28 |
Annual Report | 0003107277 | 2017-10-30 |
Annual Report | 0003107276 | 2016-11-09 |
Annual Report | 0003107275 | 2015-10-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340577196 | 1032500 | 2015-03-24 | CAVE BAY WATER TREATMENT PLANT, WORLEY, ID, 83876 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
330291816 | 1032500 | 2011-04-13 | 704 SANDPOINT AVE, WTP PIPE UPGRADE, SANDPOINT, ID, 83864 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 20462 |
Safety | Yes |
Type | Inspection |
Activity Nr | 29187 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260651 K02 |
Issuance Date | 2011-04-21 |
Current Penalty | 1500.0 |
Initial Penalty | 3000.0 |
Final Order | 2011-05-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: a) Jobsite: On or about March 30, 2011 and times prior thereto, the competent person on site did not take appropriate actions to protect employees who performed water pipe installation activities outside of the protective trench shield. These activities included but were not limited to, checking grade, installing seals and locks on the pipe, and cutting the pipe. b) Jobsite: On or about March 30, 2011 and times prior thereto, the competent person on site allowed employees to work in an estimated seven foot deep trench with near vertical walls, installing an air vac vault structure without a protective system in place. Note) Abatement certification is not required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2011-04-21 |
Current Penalty | 1500.0 |
Initial Penalty | 3000.0 |
Final Order | 2011-05-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): a) Jobsite: On or about March 30, 2011 and times prior thereto, employees working in an estimated six foot deep trench, performed water pipe installation activities outside of the protective trench shield. b) Jobsite: On or about March 30, 2011 and times prior thereto, employees working in an estimated seven foot deep, vertical walled trench, installed an air vac vault structure without a cave-in protection system in place. Note) Abatement certification is not required for this item. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19261101 F02 I |
Issuance Date | 2011-04-21 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2011-05-05 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(f)(2)(i): Each employer who has a workplace or work operation covered by this standard did not ensure that a "competent person" conducts an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace. The assessment was not completed in time to comply with requirements which are triggered by exposure data or the lack of a "negative exposure assessment," and to provide information necessary to assure that all control systems planned are appropriate for that operation and will work properly: a) JObsite: On or about March 30, and times prior thereto, the employer had not conducted an exposure assessment for workers cutting and removing up to 850 linear feet of water pipe with a coating found to contain asbestos. After it had been brought to the employers attention that the pipe may contain asbestos, and samples were sent for analysis, the employer continued to cut and remove the pipe until positive sample results were known. Note) Abatement certification is not required for this item. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19261101 G03 I |
Issuance Date | 2011-04-21 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2011-05-05 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(g)(3)(i): High-speed abrasive disc saws that were not equipped with point of cut ventilator or enclosures with HEPA filtered exhaust air were used for work related to asbestos or for work which disturbs ACM or PACM, regardless of measured levels of asbestos exposure or the results of initial exposure assessments: a) Jobsite: On or about March 30, 2011 and times prior thereto, employees were permitted to use a high speed saw to cut pipe with a coating containing asbestos. Note) Abatement certification is not required for this item. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2010-10-19 |
Emphasis | S: TRENCHING, S: STRUCK-BY, S: POWERED IND VEHICLE, S: ELECTRICAL, N: TRENCH, S: COMMERCIAL CONSTR |
Case Closed | 2011-01-13 |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 2010-12-08 |
Abatement Due Date | 2010-12-13 |
Current Penalty | 1200.0 |
Initial Penalty | 2400.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 05 |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260651 K02 |
Issuance Date | 2010-12-08 |
Abatement Due Date | 2010-12-13 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 05 |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260652 G01 III |
Issuance Date | 2010-12-08 |
Abatement Due Date | 2010-12-13 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 05 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9288307109 | 2020-04-15 | 1094 | PPP | 200 VERMEER DR, PONDERAY, ID, 83852-4901 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 17 Mar 2025