Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342802949 | 1032500 | 2017-11-08 | 656 HILLSIDE DRIVE, REXBURG, ID, 83440 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1288784 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260028 A |
Issuance Date | 2018-01-03 |
Abatement Due Date | 2018-02-28 |
Current Penalty | 815.0 |
Initial Penalty | 1630.0 |
Final Order | 2018-01-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) Jobsite: On November 8, 2017 and at times prior thereto employees performed roofing activities which required the use of a nail gun, without eye protection. Note) Certification of corrective action is required for this item. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2018-01-03 |
Abatement Due Date | 2018-02-28 |
Current Penalty | 1086.5 |
Initial Penalty | 2173.0 |
Final Order | 2018-01-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: a) Jobsite: On November 8, 2017 and at times prior thereto employees were elevated from a scaffold platform that was supported by a rough terrain forklift. A guardrail system or other fall protection system was not in place. The employees were exposed to an approximate 18 foot fall to the ground below. Note) Certification of corrective action is required for this item. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2018-01-03 |
Abatement Due Date | 2018-02-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-01-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used: a) Jobsite: On November 8, 2017 and at times prior thereto employees elevated from a scaffold platform, supported by a rough terrain forklift, without a guardrail or other fall protection system in place. The employees did not recognize or acknowledge the hazard and take action that would control or minimize the hazard. Note) Certification of corrective action IS required for this item. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19260602 D |
Issuance Date | 2018-01-03 |
Abatement Due Date | 2018-02-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-01-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.602(d): Powered industrial truck operator training. The requirements applicable to construction work under this paragraph are identical to those set forth in 29 CFR 1910.178(l) 29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer did not ensure that each operator has successfully completed the training required by this paragraph (l): a) Jobsite: On November 8, 2017 and at times prior thereto employees had not been provided with powered industrial truck (forklift) training from the employer to ensure the employees were familiar with truck related topics, workplace related topics, and safe operations. Employees operated a Pettibone , model 8042 rough terrain forklift to elevate employees to the roof structure. Note) Certification of corrective action is required for this item. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2018-01-03 |
Abatement Due Date | 2018-02-28 |
Current Penalty | 1358.0 |
Initial Penalty | 2716.0 |
Final Order | 2018-01-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) Jobsite: On or about November 8, 2017 and at times prior thereto employees performed roofing activities on a 8 in 12 pitched roof, without a fall protection system in place. Note) Certification of corrective action is required for this item. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260503 A02 III |
Issuance Date | 2018-01-03 |
Abatement Due Date | 2018-02-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-01-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On or about November 8, 2107 and at times prior thereto employees performing roofing activities on a 8 in 12 pitched roof did not recognize or acknowledge the hazard of working without a fall protection system in place. The employees did not take action to minimize the hazard. Note) Certification of corrective action is required for this item. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3878128908 | 2021-04-28 | 1087 | PPP | 3459 S Boulder Creek Ln, Ammon, ID, 83406-5113 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|