Search icon

THUNDERBIRD IRRIGATION OF IDAHO, INC.

Company Details

Name: THUNDERBIRD IRRIGATION OF IDAHO, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 24 Aug 2006 (19 years ago)
Financial Date End: 31 Aug 2024
Date dissolved: 15 Nov 2024
Entity Number: 511039
Place of Formation: IDAHO
File Number: 511039
ZIP code: 83211
County: Power County
Mailing Address: 98 FORT HALL AVE AMERICAN FALLS, ID 83211-1804

Agent

Name Role Address
BANK OF IDAHO Agent 350 MEMORIAL DRIVE, SUITE 200, IDAHO FALLS, ID 83402

President

Name Role Address Appointed On
Bob Knudsen Jr. President 98 FORT HALL AVE., AMERICAN FALLS, ID 83211 2021-06-29

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0005984149 2024-11-15
Change of Registered Office/Agent/Both (by Entity) 0005738307 2024-05-23
Annual Report 0005397673 2023-09-11
Articles of Amendment 0005030130 2022-12-14
Annual Report 0004927615 2022-09-29
Application for Reinstatement 0004327297 2021-06-29
Dissolution/Revocation - Administrative 0004058698 2020-11-05
Annual Report 0003562684 2019-07-10
Annual Report 0003562711 2019-07-10
Annual Report 0003091315 2018-06-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341958775 1032500 2016-12-06 98 FORT HALL AVE., AMERICAN FALLS, ID, 83211
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2016-12-06
Case Closed 2017-07-11

Related Activity

Type Complaint
Activity Nr 1160447
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 1086.5
Initial Penalty 2173.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Production floor and warehouse: On and before December 6, 2016 employees required to use fork trucks were not trained Note: Abatement certification is required for this item
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100178 L06
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) Production floor and warehouse: On and before December 6, 2016 employees required to use fork trucks were not certified Note: Abatement certification is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 1086.5
Initial Penalty 2173.0
Final Order 2017-03-29
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Center of the production floor: On December 6, 2016 the pipe crimper, roller had exposed rotating parts creating in-running nip points and potential caught-in hazards which were not guarded from unintentional contact (b) West corner of the production floor: On December 6, 2016 the "bull-noser" press had exposed moving parts creating pinch points which were not guarded from unintentional contact (c) Southwest wall of the production floor: On December 6, 2016 the Jet 15" variable speed drill press had was not guarded from unintentional contact Note: Abatement certification is required for this item
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100219 F03
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: (a) Mezzanine south end production floor: On December 6, 2016 the shop-made chain machine had exposed chain and sprockets which were not guarded from unintentional contact (b) Center of the production floor: On December 6, 2016 the pipe crimper had chain and which were not guarded from unintentional contact Note: Abatement certification is required for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100134 D01 III
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 815.0
Initial Penalty 1630.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) Welding area: On and before December 6, 2016, no evaluation of employee exposure to respiratory hazards was completed Note: Abatement certification is required for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Welding area and throughout facility: On and before December 6, 2016 the employer did not have a written hazard communication program for hazardous chemicals such welding gases (Argon, oxygen, acetylene) and lubricants for pipe fitting and cutting used in the production process. Note: Abatement certification is required for this item
Citation ID 01003C
Citaton Type Serious
Standard Cited 19101200 G08
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: (a) Welding area and throughout facility: On and before December 6, 2016 the employer did not make available to employees safety data sheets for hazardous chemicals such welding gases (Argon, oxygen, acetylene) and lubricants for pipe fitting and cutting used in the production process. Note: Abatement certification is required for this item
Citation ID 01003D
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2017-02-27
Abatement Due Date 2017-03-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Welding area and throughout facility: On and before December 6, 2016 the employer did not provide training for hazardous chemicals such welding gases (Argon, oxygen, acetylene) and lubricants for pipe fitting and cutting used in the production process. Note: Abatement certification is required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
1750357303 2020-04-28 1087 PPP 98 Fort Hall Avenue, AMERICAN FALLS, ID, 83211-1804
Loan Status Date 2021-04-17
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 50100
Loan Approval Amount (current) 50100
Undisbursed Amount 0
Franchise Name -
Lender Location ID 69819
Servicing Lender Name Prosperity Bank
Servicing Lender Address 1301 N Mechanic, El Campo, TX, 77437
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address AMERICAN FALLS, POWER, ID, 83211-1804
Project Congressional District ID-02
Number of Employees 10
NAICS code 221310
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 123367
Originating Lender Name Prosperity Bank
Originating Lender Address Midland, TX
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 50556.47
Forgiveness Paid Date 2021-03-25

Date of last update: 09 Apr 2025

Sources: Idaho Secretary of State