Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
1086.5 |
Initial Penalty |
2173.0 |
Final Order |
2017-03-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Production floor and warehouse: On and before December 6, 2016 employees required to use fork trucks were not trained Note: Abatement certification is required for this item |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100178 L06 |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) Production floor and warehouse: On and before December 6, 2016 employees required to use fork trucks were not certified Note: Abatement certification is required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
1086.5 |
Initial Penalty |
2173.0 |
Final Order |
2017-03-29 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Center of the production floor: On December 6, 2016 the pipe crimper, roller had exposed rotating parts creating in-running nip points and potential caught-in hazards which were not guarded from unintentional contact (b) West corner of the production floor: On December 6, 2016 the "bull-noser" press had exposed moving parts creating pinch points which were not guarded from unintentional contact (c) Southwest wall of the production floor: On December 6, 2016 the Jet 15" variable speed drill press had was not guarded from unintentional contact Note: Abatement certification is required for this item |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: (a) Mezzanine south end production floor: On December 6, 2016 the shop-made chain machine had exposed chain and sprockets which were not guarded from unintentional contact (b) Center of the production floor: On December 6, 2016 the pipe crimper had chain and which were not guarded from unintentional contact Note: Abatement certification is required for this item. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100134 D01 III |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
815.0 |
Initial Penalty |
1630.0 |
Final Order |
2017-03-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) Welding area: On and before December 6, 2016, no evaluation of employee exposure to respiratory hazards was completed Note: Abatement certification is required for this item. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Welding area and throughout facility: On and before December 6, 2016 the employer did not have a written hazard communication program for hazardous chemicals such welding gases (Argon, oxygen, acetylene) and lubricants for pipe fitting and cutting used in the production process. Note: Abatement certification is required for this item |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: (a) Welding area and throughout facility: On and before December 6, 2016 the employer did not make available to employees safety data sheets for hazardous chemicals such welding gases (Argon, oxygen, acetylene) and lubricants for pipe fitting and cutting used in the production process. Note: Abatement certification is required for this item |
|
Citation ID |
01003D |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2017-02-27 |
Abatement Due Date |
2017-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Welding area and throughout facility: On and before December 6, 2016 the employer did not provide training for hazardous chemicals such welding gases (Argon, oxygen, acetylene) and lubricants for pipe fitting and cutting used in the production process. Note: Abatement certification is required for this item. |
|