346774326
|
1032500
|
2023-06-15
|
3000 NW MARATHON WAY, MOUNTAIN HOME, ID, 83647
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-06-15
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2024-04-30
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100219 C04 I |
Issuance Date |
2023-09-21 |
Abatement Due Date |
2024-05-01 |
Current Penalty |
7812.5 |
Initial Penalty |
15625.0 |
Final Order |
2023-10-19 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) projected more than one half the diameter of the shaft: a) A-4 Slice Line: On or about June 15, 2023, employees were exposed to unguarded, rotating shaft ends, located approximately two feet above ground level and adjacent to the walkway along the process line. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2023-09-21 |
Abatement Due Date |
2023-10-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-10-19 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) #5 Shredder Line: On or about June 15, 2023, the powered, rotating shaft used to rotate the tumble drum was not guarded. The shaft is approximately three feet long and near a frequently used walkway. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2023-09-21 |
Abatement Due Date |
2023-10-18 |
Current Penalty |
0.0 |
Initial Penalty |
12278.0 |
Final Order |
2023-10-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On June 15, 2023 and at times prior thereto, the A-2 Hayssen line was not locked out/tagged out before performing servicing and maintenance activities. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-09-21 |
Abatement Due Date |
2023-10-18 |
Current Penalty |
51566.9 |
Initial Penalty |
73667.0 |
Final Order |
2023-10-19 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) A-4 Hayssen Line: On or about June 15, 2023, employees were exposed to caught-in hazards associated with rotary clamps when unjamming packaging of cheese slices. Marathon Cheese Corporation was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1543074, citation number 1, item number 2a and was affirmed as a final order on 11-03-2021, with respect to a workplace located at 304 East St., Marathon, WI 54448. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100147 C05 II D |
Issuance Date |
2023-09-21 |
Abatement Due Date |
2023-10-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-10-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(5)(ii)(D):Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): a) On June 15, 2023, locks and tags applied to the Schwindler & Wagner by employees performing maintenance, did not identify the employees who applied the lock. |
|
|
343699302
|
1032500
|
2019-01-08
|
3000 NW MARATHON WAY P.O. BOX 1510, MOUNTAIN HOME, ID, 83647
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-01-08
|
Case Closed |
2019-02-19
|
Related Activity
Type |
Complaint |
Activity Nr |
1414010 |
Health |
Yes |
|
|
339842817
|
1032500
|
2014-07-09
|
3000 NW MARATHON WAY P.O. BOX 1510, MOUNTAIN HOME, ID, 83647
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-07-09
|
Emphasis |
P: SSTARG12, N: SSTARG12
|
Case Closed |
2014-08-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2014-07-30 |
Abatement Due Date |
2014-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-25 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) The employer maintains energy control procedures for equipment that includes the Line A-3 Slicer, Line D-3 and the Conveyor Belt, and the C-2 Shredder. The employer has not annually conducted a periodic inspection of the energy control procedures for this equipment. Abatement certification is required for this item. |
|
|
315027433
|
1032500
|
2011-01-11
|
3000 NW MARATHON WAY, MOUNTAIN HOME, ID, 83647
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-01-12
|
Emphasis |
N: SSTARG10
|
Case Closed |
2011-05-26
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100120 Q01 |
Issuance Date |
2011-02-23 |
Abatement Due Date |
2011-04-11 |
Current Penalty |
3060.0 |
Initial Penalty |
3060.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100120 Q02 II |
Issuance Date |
2011-02-23 |
Abatement Due Date |
2011-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100120 Q02 X |
Issuance Date |
2011-02-23 |
Abatement Due Date |
2011-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100120 Q06 |
Issuance Date |
2011-02-23 |
Abatement Due Date |
2011-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19100134 D01 III |
Issuance Date |
2011-02-23 |
Abatement Due Date |
2011-05-11 |
Current Penalty |
2000.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01001F |
Citaton Type |
Serious |
Standard Cited |
19101200 H03 I |
Issuance Date |
2011-02-23 |
Abatement Due Date |
2011-05-11 |
Nr Instances |
1 |
Nr Exposed |
240 |
Gravity |
05 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100212 A01 |
Issuance Date |
2011-02-23 |
Abatement Due Date |
2011-03-14 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
|
311578520
|
1032500
|
2008-09-23
|
3000 NW MARATHON WAY, MOUNTAIN HOME, ID, 83647
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-09-24
|
Case Closed |
2008-10-27
|
Related Activity
Type |
Complaint |
Activity Nr |
200248060 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2008-10-23 |
Abatement Due Date |
2008-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
|