Search icon

ROUGHNECK CONSTRUCTION, LLC

Company Details

Name: ROUGHNECK CONSTRUCTION, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 26 Jan 2016 (9 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 489870
Place of Formation: IDAHO
File Number: 489870
ZIP code: 83234
County: Bannock County
Principal Address: PO BOX 144 DOWNEY, ID 83234
Mailing Address: 8755 S OLD HIGHWAY 191 MALAD CITY, ID 83252-6573

Agent

Name Role Address
DIANNA BURDEN Agent 265 N 100 E ST, DOWNEY, ID 83234

Member

Name Role Address Appointed On
Laura Higley Member 343 BANNOCK ST, MALAD CITY, ID 83252 2020-12-18

Filing

Filing Name Filing Number Filing date
Annual Report 0006031833 2024-12-19
Annual Report 0005591158 2024-02-07
Annual Report 0005093275 2023-02-03
Annual Report 0004580956 2022-01-25
Annual Report 0004104117 2020-12-18
Annual Report 0003742865 2020-01-09
Annual Report 0003409580 2019-01-23
Annual Report 0003033289 2017-12-07
Annual Report 0003033288 2016-11-22
Initial Filing 0000489870 2016-01-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347350431 1032500 2024-03-14 AMMON ROAD, POCATELLO, ID, 83201
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-03-14
Emphasis L: FALL, N: FALL
Case Closed 2024-06-04

Related Activity

Type Referral
Activity Nr 2141677
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-04-08
Current Penalty 1037.0
Initial Penalty 2074.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On March 14, 2024, and times prior employees used pneumatic staple guns without eye protection. Note) Corrected during inspection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-04-08
Current Penalty 1469.5
Initial Penalty 2939.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On March 14, 2024, and times prior employees performing sheathing on a multi-family housing unit with a 6 in 12 pitched roof were exposed to fall hazards of 18 to 20 feet from eave to ground. b) On March 14, 2024, and times prior employees performing sheathing a multi-family housing unit were exposed to a 10- foot fall hazard at the open sided floor around multiple stairway openings on the second floor. Note) Corrected during inspection.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-04-08
Abatement Due Date 2024-05-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-10
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On March 14, 2024, and times prior employees did not recognize the hazard of working without personal fall protection or take actions needed to minimize the hazard. b) On March 14, 2024, and times prior employees did not recognize the hazard of walking/working near open sided floors or take actions needed to minimize the hazard. c) On March 14, 2024, and times prior employees did not recognize the hazard of not having handrails on stairways in the event of a trip and fall down the stairs or take actions needed to minimize the hazard. Note) Certification of corrective action is required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2024-04-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On March 14, 2024, and times prior employees used interior stairways where handrails were not installed. Note) Corrected during inspection.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4619697200 2020-04-27 1087 PPP 343 BANNOCK ST, MALAD, ID, 83252
Loan Status Date 2021-02-10
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 43600
Loan Approval Amount (current) 43600
Undisbursed Amount 0
Franchise Name -
Lender Location ID 106784
Servicing Lender Name America First FCU
Servicing Lender Address 1344 West 4675 South, RIVERDALE, UT, 84405-3690
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address MALAD, ONEIDA, ID, 83252-0001
Project Congressional District ID-02
Number of Employees 4
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 106784
Originating Lender Name America First FCU
Originating Lender Address RIVERDALE, UT
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 43862.79
Forgiveness Paid Date 2020-12-08

Date of last update: 09 Apr 2025

Sources: Idaho Secretary of State