Search icon

PHOENIX FRAMING, LLC

Company Details

Name: PHOENIX FRAMING, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 26 Jan 2016 (9 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 489830
Place of Formation: IDAHO
File Number: 489830
ZIP code: 83687
County: Canyon County
Principal Address: 817 GARDEN VALLEY ST NAMPA, ID 83687
Mailing Address: 4961 ANDERSON WAY NAMPA, ID 83687

Agent

Name Role Address
MAGALY AVILA Agent 4961 ANDERSON WAY, NAMPA, ID 83687

Manager

Name Role Address Appointed On
Martin Avila Manager 817 LITTLE VALLEY ST, NAMPA, ID 83687-8686 2022-04-26
Martin Avila Araujo Manager 4961 ANDERSON WAY, NAMPA, ID 83687 2025-01-31

Member

Name Role Address Appointed On Resigned On
Martin Avila Araujo Member 817 LITTLE VALLEY ST, NAMPA, ID 83687 2021-02-21 2022-04-26

Filing

Filing Name Filing Number Filing date
Annual Report 0006086147 2025-01-31
Annual Report 0005613819 2024-02-26
Annual Report 0005072685 2023-01-17
Application for Reinstatement 0004716399 2022-04-26
Dissolution/Revocation - Administrative 0004702442 2022-04-19
Annual Report 0004179295 2021-02-21
Annual Report 0003724936 2020-01-01
Annual Report 0003434513 2019-02-21
Annual Report 0003033192 2018-02-24
Annual Report 0003033191 2017-02-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344117460 1032500 2019-06-26 LOT 4 BLOCK 2 DRY CREEK RANCH, BOISE, ID, 83714
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2019-06-26
Emphasis L: FALL
Case Closed 2019-11-04

Related Activity

Type Inspection
Activity Nr 1411751
Safety Yes
Type Referral
Activity Nr 1470412
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-09-02
Current Penalty 2000.0
Initial Penalty 3978.0
Final Order 2019-11-04
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about June 26, 2019, and at times prior thereto, employees performing framing activities without fall protection in place, were exposed to fall hazards of approximately 15 - 20 feet. (b) On or about June 26, 2019, and at times prior thereto, employees performing framing activities exposed to fall hazards from a window opening with a sill height of 26 to 27 inches. Note: Abatement certification is not required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2019-09-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-11-04
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: (a) On or about June 26, 2019, and at times prior thereto, employees performing framing activities were exposed to falls while using the stairs to access the second floor. Note: Abatement certification is not required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-09-02
Abatement Due Date 2019-09-12
Current Penalty 1500.0
Initial Penalty 2842.0
Final Order 2019-11-04
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about June 26, 2019, and at times prior thereto, employees were exposed to falls of approximately 18 feet while using a ladder that extended approximately 1 foot above the landing. Note: Abatement certification is required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2019-09-02
Abatement Due Date 2019-09-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-11-04
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) On or about June 26, 2019, and at times prior thereto, employees performing framing activities were using a hand held circular saw with a frayed cord. Note: Abatement certification is required for this item.