Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-05-17
|
Emphasis |
L: FALL
|
Case Closed |
2012-08-14
|
Related Activity
Type |
Inspection |
Activity Nr |
445113 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
445196 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
367248 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2012-06-18 |
Current Penalty |
700.0 |
Initial Penalty |
867.0 |
Final Order |
2012-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. (a) Hwy 95 and D Street, on or about May 17, 2012, and at time prior thereto, employees conducting roofing work on the North side of the building were approximately 9 feet above the ground with fall protection. Note: Abatement certification is not required for this item. Item was corrected at the time of the inspection. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2012-06-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) North side of Anytime Fitness building, on or about May 17, 2012, and at times prior thereto, employees used an eight foot step ladder to access the roof area approximately nine feet above the ground. Note: Abatement certification is not required for this item. Item was corrected at the time of the inspection. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2012-06-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-07-23 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) North side of Anytime Fitness building, on or about May 17, 2012, and at times prior thereto, employee(s) using an eight foot step ladder to access the roof area approximately nine feet above the ground was standing on the top step to do work. Note: Abatement certification is not required for this item. Item was corrected at the time of the inspection. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19261053 B14 |
Issuance Date |
2012-06-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(14): Cross-bracing, not designed for climbing, on the rear section of (a) stepladder(s) was used for climbing: (a) North side of Anytime Fitness building, on or about May 17, 2012, and at times prior thereto, employee(s) using an eight foot step ladder to access the roof area approximately nine feet above the ground was standing on the cross bracing to do work. Note: Abatement certification is not required for this item. Item was corrected at the time of the inspection. |
|
|