347895179
|
1032500
|
2024-11-21
|
RAMSEY RD, HAYDEN, ID, 83835
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-11-21
|
Emphasis |
N: CTARGET, P: CTARGET
|
|
343068607
|
1032500
|
2018-04-04
|
HANLEY ST & RAMSEY ST., COEUR D ALENE, ID, 83814
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-04-04
|
Emphasis |
N: TRENCH
|
Case Closed |
2018-04-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1264237 |
Safety |
Yes |
|
|
342642378
|
1032500
|
2017-09-16
|
PRAIRIE AVENUE BETWEEN SPOKANE AND CHASE ROAD, POST FALLS, ID, 83854
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-09-16
|
Emphasis |
N: TRENCH
|
Case Closed |
2018-09-27
|
Related Activity
Type |
Referral |
Activity Nr |
1264558 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2017-11-17 |
Abatement Due Date |
2018-01-08 |
Current Penalty |
0.0 |
Initial Penalty |
8873.0 |
Final Order |
2018-01-11 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: (a) On September 16, 2017 and at times prior thereto; the employer did not ensure that a competent person implemented and inspected the traffic control plan, thus exposing the employees to struck-by hazards. NOTE: Abatement certification and documentation IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260200 G01 |
Issuance Date |
2017-11-17 |
Abatement Due Date |
2017-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-01-11 |
Nr Instances |
2 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.200(g)(1): Construction areas were not posted with legible traffic signs at points of hazards: (a) On September 16, 2017 and at times prior thereto; the employer did not provide at least one advance warning sign in the westbound lane to warn road users of work that was taking place and that the shoulder was closed, thus exposing employees to work zone struck-by hazards. ABATEMENT NOTE: Reference MUTCD standards 6G2-b(4) that require advance warning or advance warning signs to show a point of hazard. NOTE: Abatement certification and documentation IS required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260651 D |
Issuance Date |
2017-11-17 |
Abatement Due Date |
2017-12-14 |
Current Penalty |
6000.0 |
Initial Penalty |
0.0 |
Final Order |
2018-01-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(d): Employees exposed to public vehicular traffic were not provided with a warning vest or other suitable garments marked with or made of reflectorized or high-visibility material: (a) On or about September 16, 2017 and at times prior thereto; the employer did not ensure that employees wore a warning vest or similar while working at an excavation on the shoulder with encroachment into the roadway, exposing them to struck-by hazards. NOTE: Abatement certification and documentation IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260651 K02 |
Issuance Date |
2017-11-17 |
Abatement Due Date |
2017-12-14 |
Current Penalty |
8500.0 |
Initial Penalty |
8873.0 |
Final Order |
2018-01-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. (a) On or about September 16, 207 and at times prior thereto, employees had not been removed from an excavation when the presence of information clearly showed hazards were present. NOTE: Abatement certification and documentation IS required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260651 E |
Issuance Date |
2017-11-17 |
Abatement Due Date |
2017-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-01-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(e): Employee was not prohibited to be underneath loads handled by lifting or digging equipment: (a) On or about September 16, 2017 and at times prior thereto; two employees were exposed to crushing hazards while working in an excavation while one excavator removed soil and another backfilled. NOTE: Abatement certification and documentation IS required for this item. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2017-11-17 |
Abatement Due Date |
2017-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
17745.0 |
Final Order |
2018-01-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation are not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) of this section. a) On or about September 16, 2017, and at times prior thereto: the employer did not protect two employees working in an excavation estimated to be 6 feet deep with near vertical walls and within a foot from a two-way road with heavy traffic traveling at 40 mph, from cave-in hazards by properly sloping or using appropriate protective systems. NOTE: Abatement certification and documentation IS required for this item. MDM Construction, Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 459376, citation number 1, item number 1b and was affirmed as final order on March 14, 2013, with respect to a workplace located at 5675 Government Way, Coeur D'Alene, ID 83814. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260651 C02 |
Issuance Date |
2017-11-17 |
Abatement Due Date |
2017-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
17745.0 |
Final Order |
2018-01-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) On or about September 16, 2017 and at times prior thereto: the employer did not provide two employees a safe means of egress while working in an excavation approximately 6 feet deep with nearly vertical walls and within a foot of a two way road with heavy traffic traveling at 40 mph. NOTE: Abatement certification and documentation IS required for this item. MDM Construction, Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 459376, citation number 2, item number 1 and was affirmed as final order on March 14, 2013, with respect to a workplace located at 5675 Government Way, Coeur D'Alene, ID 83814. |
|
|
339029696
|
1032500
|
2013-04-10
|
12405 GOVERNMENT WAY, HAYDEN, ID, 83835
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-04-10
|
Emphasis |
L: FALL
|
Case Closed |
2013-07-30
|
Related Activity
Type |
Referral |
Activity Nr |
815594 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260453 B02 V |
Issuance Date |
2013-05-10 |
Abatement Due Date |
2013-05-10 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-05-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) 12405 Government Way, Hayden, ID: On or about April 10, 2013, two employee's without a personal fall arrest systems were observed working in a Genie S40 aerial lift extended up to heights of approximately 15 feet above ground . Note: Abatement certification IS NOT required for this item. |
|
|
334593761
|
1032500
|
2012-05-31
|
5675 GOVERNMENT WAY, COEUR D ALENE, ID, 83814
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-05-31
|
Emphasis |
N: TRENCH
|
Case Closed |
2013-03-14
|
Related Activity
Type |
Referral |
Activity Nr |
384837 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
2012-08-23 |
Current Penalty |
1785.0 |
Initial Penalty |
2380.0 |
Contest Date |
2012-09-19 |
Final Order |
2013-02-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection was not provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) West side of the trench: On or about May 31, 2012 and at times prior thereto, two employees were working in a trench where the spoil pile was not set back by at least two feet. Note: Abatement certification is not required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2012-08-23 |
Abatement Due Date |
2012-09-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2012-09-19 |
Final Order |
2013-02-25 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section. a) South end of the trench: On or about May 31, 2012 and at times prior thereto, an employee was exposed to a 5.6 foot deep unprotected trench. b) North end of the trench: On or about May 31, 2012 and at times prior thereto, an employee was exposed to a 6.3 foot deep unprotected trench. Note: Abatement certification is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260651 C02 |
Issuance Date |
2012-08-23 |
Abatement Due Date |
2012-09-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2012-09-19 |
Final Order |
2013-02-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. a) On or about May 31, 2012 and at times prior thereto, two employees were working in a trench without a safe means of egress. Note: Abatement certification is required for this item. |
|
|
334197076
|
1032500
|
2012-04-18
|
NW BLVD E NIC, COEUR D ALENE, ID, 83814
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-04-18
|
Emphasis |
N: CTARGET
|
Case Closed |
2012-04-18
|
Related Activity
Type |
Inspection |
Activity Nr |
419923 |
Safety |
Yes |
|
|
313355810
|
1032500
|
2010-07-14
|
WALMART, COEUR D'ALENE, ID, 83835
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-07-14
|
Emphasis |
N: TRENCH, S: TRENCHING
|
Case Closed |
2010-07-14
|
Related Activity
Type |
Referral |
Activity Nr |
200250363 |
Safety |
Yes |
Health |
Yes |
|
|
313353534
|
1032500
|
2010-04-21
|
402 W. HONEYSUCKLE, HAYDEN, ID, 83835
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-04-21
|
Emphasis |
L: IDCONSUB, S: POWERED IND VEHICLE
|
Case Closed |
2010-08-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2010-05-12 |
Abatement Due Date |
2010-05-17 |
Current Penalty |
700.0 |
Initial Penalty |
1125.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
|
313353518
|
1032500
|
2010-04-21
|
402 W. HONEYSUCKLE, HAYDEN, ID, 83835
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-04-21
|
Emphasis |
L: IDCON, S: COMMERCIAL CONSTR
|
Case Closed |
2010-05-10
|
|
313348336
|
1032500
|
2009-07-09
|
PRIEST LAKE, PRIEST RIVER, ID, 83856
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-07-09
|
Case Closed |
2009-07-13
|
|