Search icon

Patota's Framing LLC

Company Details

Name: Patota's Framing LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 01 Sep 2022 (3 years ago)
Financial Date End: 30 Sep 2024
Date dissolved: 13 Dec 2024
Entity Number: 4875411
Place of Formation: IDAHO
File Number: 839095
ZIP code: 83615
County: Valley County
Principal Address: 26 TIMBERLINE RD DONNELLY, ID 83615
Mailing Address: PO BOX 2184 MCCALL, ID 83638-2184

Agent

Name Role Address
Gerardo Alfaro Agent 12861 NORTHWIND, DONNELLY, ID 83615

Member

Name Role Address Appointed On
Gerardo Alfaro Member 12861 NORTHWIND, DONNELLY, ID 83615 2023-09-06

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0006023254 2024-12-13
Annual Report 0005385292 2023-09-06
Initial Filing 0004875411 2022-09-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347524456 1032500 2024-05-29 508 VIRGINIA AVE, NEW MEADOWS, ID, 83654
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-05-29
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2169247
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-07-26
Abatement Due Date 2024-08-14
Current Penalty 1037.0
Initial Penalty 2074.0
Final Order 2024-09-10
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On May 29, 2024, and times prior employees performing framing activities using pneumatic nail guns were not wearing safety glasses. Note) Certification of corrective action is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-07-26
Current Penalty 1728.5
Initial Penalty 3457.0
Final Order 2024-09-10
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On May 29, 2024, and times prior employees performed framing activities on a multi-family housing unit with a 4 in 12 pitched roof. The employees were not using fall protection and were exposed to 18 to 25-foot fall hazards to the ground below. Note) Corrected during inspection.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-07-26
Abatement Due Date 2024-08-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On May 29, 2024, and times prior employees performing framing activities did not recognize the hazard of working from heights without fall protection or take actions needed to minimize their exposure to the hazard. Note) Certification of corrective action is required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-07-26
Current Penalty 1728.5
Initial Penalty 3457.0
Final Order 2024-09-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed: a) On May 29, 2024, and times prior employees were exposed to an 18-foot fall hazard when using an extension ladder for access to the sheathed roof work area. The ladder extended only one rung beyond the roof edge. Note) Corrected during inspection.