Search icon

DAUM CONSTRUCTION, LLC

Company Details

Name: DAUM CONSTRUCTION, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 04 Jan 2016 (9 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 486147
Place of Formation: IDAHO
File Number: 486147
ZIP code: 83835
County: Kootenai County
Principal Address: PO BOX 3381 HAYDEN, ID 83835
Mailing Address: PO BOX 3381 HAYDEN, ID 83835-3381

Agent

Name Role Address
William R. Daum Agent 11836 N REED RD, HAYDEN, ID 83835

Member

Name Role Address Appointed On
William R Daum Member PO BOX 3381, HAYDEN, ID 83835 2020-12-07

Filing

Filing Name Filing Number Filing date
Annual Report 0006045595 2025-01-03
Annual Report 0005540845 2024-01-04
Annual Report 0005029135 2022-12-13
Annual Report Amendment 0004619177 2022-02-21
Annual Report Amendment 0004615771 2022-02-18
Annual Report 0004526714 2021-12-13
Annual Report 0004091457 2020-12-07
Annual Report 0003707358 2019-12-11
Annual Report 0003412462 2019-01-26
Annual Report 0003022064 2017-12-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347502593 1032500 2024-05-23 11546 N WARREN ST, HAYDEN, ID, 83835
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-05-23
Emphasis L: FORKLIFT, N: FALL, P: FALL
Case Closed 2024-08-19

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260028 A
Issuance Date 2024-06-24
Abatement Due Date 2024-07-19
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) On or about May 23, 2024, and at times prior thereto employees used pneumatic nail guns during framing activities, without eye protection. Note: Certification of corrective action is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-06-24
Abatement Due Date 2024-07-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a):Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, was not protected by protective helmets. a) On or about May 23, 2024, and at times prior thereto; an employee worked below other employees who were installing OSB sheathing onto the roof, 24 feet overhead. Note: Certification of corrective action is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2024-06-24
Abatement Due Date 2024-07-19
Current Penalty 4839.0
Initial Penalty 4839.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about May 23, 2024 and at times prior thereto employees performed framing activities, which included roof sheathing, on a 2-12 pitched roof and were exposed to fall hazards of approximately 24 feet. Note: Abatement and Certification of corrective action ARE required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260602 D
Issuance Date 2024-06-24
Abatement Due Date 2024-07-19
Current Penalty 4839.0
Initial Penalty 4839.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(d): Powered industrial truck operator training. The requirements applicable to construction work under this paragraph are identical to those set forth in 29 CFR 1910.178(l) 29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer did not ensure that each operator has successfully completed the training required by this paragraph (l): a) On or about May 23, 2024 and at times prior thereto; an employee operated a GEHL Dynalift rough terrain forklift. Note) Abatement and Certification of corrective action and documentation and documentation ARE required for this item.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2024-06-24
Abatement Due Date 2024-07-19
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On May 23, 2024, employees used the top step of an 8-foot A-Frame ladder placed on the second story floor to get down from the rafters. Abatement Note: Abatement on-site
342424595 1032500 2017-06-22 4148 E 16TH AVENUE, POST FALLS, ID, 83854
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-06-22
Case Closed 2018-10-11

Related Activity

Type Referral
Activity Nr 1233699
Safety Yes
Type Inspection
Activity Nr 1242630
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260028 A
Issuance Date 2017-07-13
Abatement Due Date 2017-08-08
Current Penalty 1500.0
Initial Penalty 2173.0
Final Order 2017-08-03
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) Jobsite: On June 22, 2017 and at times prior thereto employees performed framing activities which required the use of a nail guns and skillsaws; without eye protection. Note) Certification of corrective action is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2017-07-13
Abatement Due Date 2017-08-08
Current Penalty 3750.0
Initial Penalty 5070.0
Final Order 2017-08-03
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person and were not constructed and loaded in accordance with that design: a) Jobsite: On June 22, 2017 and at times prior thereto employees performed framing activities from a scaffold platform that was supported by a rough terrain forklift. The scaffold platform was not designed and constructed by a qualified person in that the platform was not secured to the forklift. The employees were exposed to an approximate 18 foot fall to the ground below. b) Jobsite: On June 22, 2017 and at times prior thereto employees performed framing activities from a scaffold platform that was supported by a rough terrain forklift. The scaffold platform was not designed and constructed by a qualified person in that a guardrail system or other fall protection system was not in place. The employees were exposed to a 18 foot fall to the ground below. c) Jobsite: On June 22, 2017 and at times prior thereto employees performed framing activities from a scaffold platform that was supported by a rough terrain forklift. The scaffold platform was not designed and constructed by a qualified person in that the manufacturer warned of a personal injury hazard, prohibiting use of the machine as a personal lift, or to fit the machine with any form of personnel work platform. The employees were exposed to a 18 foot fall to the ground below. Note) Abatement and Certification of corrective action ARE required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2017-07-13
Abatement Due Date 2017-08-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-03
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: a) Jobsite: On June 22, 2017 and at times prior thereto employees performed framing activities from a scaffold platform that was supported by a rough terrain forklift. A guardrail system or other fall protection system was not in place. The employees were exposed to an approximate 18 foot fall to the ground below. Note) Abatement and Certification of corrective action ARE required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260602 D
Issuance Date 2017-07-13
Abatement Due Date 2017-08-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-03
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(d): Powered industrial truck operator training. The requirements applicable to construction work under this paragraph are identical to those set forth in 29 CFR 1910.178(l) 29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer did not ensure that each operator has successfully completed the training required by this paragraph (l): a) Jobsite: On June 22, 2017 and at times prior thereto employees had not been provided with powered industrial truck (forklift) training from the employer to ensure the employees were familiar with truck related topics, workplace related topics, and safe operations. Employees operated a GEHL dynalift rough terrain forklift while performing framing activities. Note) Abatement and Certification of corrective action ARE required for this item.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2017-07-13
Abatement Due Date 2017-08-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-03
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used: a) Jobsite: On June 22, 2017 and at times prior thereto employees performed framing activities from a scaffold platform, supported by a rough terrain forklift, without a guardrail or other fall protection system in place. The employees did not recognize or acknowledge the hazard and take action that would control or minimize the hazard. b) Jobsite: On June 22, 2017 and at times prior thereto employees performed framing activities from a scaffold platform, supported by a rough terrain forklift. The platform was not securely attached to the forklift. The employees did not recognize or acknowledge the hazard and take action that would control or minimize the hazard. Note) Abatement and Certification of corrective action ARE required for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-07-13
Abatement Due Date 2017-08-08
Current Penalty 3750.0
Initial Penalty 5070.0
Final Order 2017-08-03
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) Jobsite: On or about June 22, 2017 and at times prior thereto employees performed framing activities, which included roof sheathing, on a 5 1/2 in 12 pitched roof, without using a fall protection system in place on the balconies. Employees were exposed to fall hazards ranging approximately 9 feet up to 25 feet. Note) Abatement and Certification of corrective action ARE required for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A02 III
Issuance Date 2017-07-13
Abatement Due Date 2017-08-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-03
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On or about June 22, 2107 and at times prior thereto employees performing framing activities on a 5 1/2 in 12 pitched roof did not recognize and/or acknowledge the hazard of working without a fall protection system in place on the balcony levels. The employees did not take action to minimize the hazard. Note) Abatement and Certification of corrective action ARE required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9883037007 2020-04-09 1094 PPP 10843 N Lakeview Dr, HAYDEN, ID, 83835-9088
Loan Status Date 2021-02-19
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 95512.5
Loan Approval Amount (current) 95512.5
Undisbursed Amount 0
Franchise Name -
Lender Location ID 41844
Servicing Lender Name First Interstate Bank
Servicing Lender Address 401 N 31st St, BILLINGS, MT, 59101-1200
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address HAYDEN, KOOTENAI, ID, 83835-9088
Project Congressional District ID-01
Number of Employees 15
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 41844
Originating Lender Name First Interstate Bank
Originating Lender Address BILLINGS, MT
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 96219.03
Forgiveness Paid Date 2021-01-07

Date of last update: 09 Apr 2025

Sources: Idaho Secretary of State