Name: | RON J. PETERSON CONSTRUCTION, INC. |
Jurisdiction: | Idaho |
Legal type: | Foreign Business Corporation |
Status: | Active-Good Standing |
Date of registration: | 11 May 2022 (3 years ago) |
Financial Date End: | 31 May 2025 |
Entity Number: | 4742482 |
Place of Formation: | UTAH |
File Number: | 821928 |
Principal Address: | 1267 WILLIS ST. STE 200 REDDING, CA 96001 |
Mailing Address: | 1942 BROADWAY ST. STE 314C BOULDER, CO 80302 |
Name | Role | Address |
---|---|---|
NORTHWEST REGISTERED AGENT LLC | Agent | 784 S CLEARWATER LOOP STE B, POST FALLS, ID 83854 |
Name | Role | Address | Appointed On |
---|---|---|---|
Ron Peterson | Director | 1532 S 1100 W, OGDEN, UT 84404 | 2023-04-03 |
Name | Role | Address | Appointed On |
---|---|---|---|
Lori Durbanio | Treasurer | 1532 SOUTH 1100 WEST, OGDEN, UT 84404 | 2024-04-30 |
Name | Role | Address | Appointed On |
---|---|---|---|
Lori Durbanio | Secretary | 1532 SOUTH 1100 WEST, OGDEN, UT 84404 | 2024-04-30 |
Name | Role | Address | Appointed On |
---|---|---|---|
Ron Peterson | President | 1532 S 1100 W, OGDEN, UT 84404 | 2024-04-30 |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005708284 | 2024-04-30 |
Annual Report | 0005174100 | 2023-04-03 |
Initial Filing | 0004742482 | 2022-05-11 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
331073601 | 1032500 | 2011-09-19 | 281 E HOOPER AVENUE, SODA SPRINGS, ID, 83230 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 81355 |
Safety | Yes |
Type | Inspection |
Activity Nr | 106996 |
Safety | Yes |
Type | Inspection |
Activity Nr | 106998 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2012-01-03 |
Abatement Due Date | 2012-01-25 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-01-18 |
Nr Instances | 2 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) North side of Roof: On September 19, 2011, employees were exposed to a fall hazard of approximately 11 feet when they walked up the north side a 5:12 roof without fall protection to gain access to their work area. (b) South Side of Roof: On September 19, 2011, employees were exposed to a fall hazard of approximately 16 feet while working around a roof access point on the south side of the 5:12 roof without fall protection. Note: Abatement certification IS required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B20 |
Issuance Date | 2012-01-03 |
Abatement Due Date | 2012-01-25 |
Current Penalty | 1050.0 |
Initial Penalty | 2100.0 |
Final Order | 2012-01-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(20): Employees did not face the ladder when ascending or descending the ladder: (a) North Side of Roof: On September 19, 2011, an employee descended the ladder with his back to the ladder. Note: Abatement certification IS required for this item. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19040033 A |
Issuance Date | 2012-01-03 |
Abatement Due Date | 2012-01-25 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-01-18 |
Nr Instances | 1 |
Nr Exposed | 30 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR �1904.33(a): The OSHA 300 Log, the privacy case list (if one exists), the OSHA 300A Summary, and/or the OSHA 301 Incident Reports (or equivalents), were not retained in the establishment for 5 years following the end of the calendar year to which they relate: (a) Company Office: On September 26, 2011 and at times prior thereto, the OSHA 300 Log for calendar year 2008 was not located or available upon request. Note: Abatement certification IS required for this item. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260100 A |
Issuance Date | 2012-01-03 |
Abatement Due Date | 2012-01-25 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-01-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) Ground level below roof workers: On September 19, 2011, employees were exposed to the hazard of being struck by falling debris resulting from roof tear-off when the employees exited the building or ascended/descended a ladder without head protection. Note: Abatement certification IS required for this item. |
Date of last update: 25 Mar 2025
Sources: Idaho Secretary of State