339063109
|
1032500
|
2013-05-09
|
2212 INDUSTRIAL RD., NAMPA, ID, 83687
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-10
|
Case Closed |
2013-07-22
|
Related Activity
Type |
Complaint |
Activity Nr |
814126 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2013-06-19 |
Abatement Due Date |
2013-07-16 |
Current Penalty |
800.0 |
Initial Penalty |
1607.0 |
Final Order |
2013-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Saw Shop, east wall: on May 9, 2013, and at times prior thereto, two branch circuits in a panelboard were not legibly marked as to their purpose. NOTE: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2013-06-19 |
Abatement Due Date |
2013-07-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: a) Saw Shop, east wall: on May 9, 2013, and at times prior thereto, an electrical cabinet had accessible live bus bars due to open breaker knockouts. NOTE: Abatement for this item IS rquired. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100141 A03 |
Issuance Date |
2013-06-19 |
Abatement Due Date |
2013-07-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(a)(3): The employer did not ensure that all places of employment were kept clean to the extent that the nature of the work allowed. a) Plant # 1, Skin Shop, on May 9, 2013, and at times prior thereto, the "Hydrapower" hydraulic shear leaked fluids from its oil reservoir and hydraulic unit onto the workroom floor. NOTE: Citation abatement for this item IS required. |
|
|
338952955
|
1032500
|
2013-03-12
|
2212 INDUSTRIAL ROAD, NAMPA, ID, 83687
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2013-03-12
|
Case Closed |
2013-04-25
|
Related Activity
Type |
Complaint |
Activity Nr |
807283 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100132 D01 |
Issuance Date |
2013-03-22 |
Abatement Due Date |
2013-04-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-04-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) Grinding/Prep Area: On or about March 12, 2013 and at times prior thereto, the area in which employees were working with Technichem Brute Liquid degreaser had not been assessed for hazards associated with utilizing the degreaser as a spray. Note: Abatement certification is required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100134 G01 I A |
Issuance Date |
2013-03-22 |
Abatement Due Date |
2013-03-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) Paint booth area: On or about March 12, 2013 and at times prior thereto, an employee requried to wear a tight fitting 3M respirator had facial hair that interfered with the seal of the respirator. Note: Abatement certification is required for this item. |
|
|
306440116
|
1032500
|
2004-08-13
|
2212 INDUSTRIAL RD., NAMPA, ID, 83687
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2004-08-16
|
Case Closed |
2005-01-10
|
Related Activity
Type |
Complaint |
Activity Nr |
200236792 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100179 N03 VI |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Current Penalty |
620.0 |
Initial Penalty |
1225.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
05 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 VI |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Current Penalty |
260.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100107 G02 |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 I |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 C02 |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Current Penalty |
260.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100095 D01 |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Nr Instances |
3 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100095 K01 |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Nr Instances |
3 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 H03 III |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02003A |
Citaton Type |
Other |
Standard Cited |
19100134 E01 |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
Citation ID |
02003B |
Citaton Type |
Other |
Standard Cited |
19100134 F01 |
Issuance Date |
2004-10-04 |
Abatement Due Date |
2004-11-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
|