Search icon

EARLY BIRD SUPPLY, INC.

Company Details

Name: EARLY BIRD SUPPLY, INC.
Jurisdiction: Idaho
Legal type: Foreign Business Corporation
Status: Active-Good Standing
Date of registration: 14 Dec 2021 (3 years ago)
Financial Date End: 31 Dec 2025
Entity Number: 4525936
Place of Formation: WASHINGTON
File Number: 795137
Principal Address: 1508 15TH ST CLARKSTON, WA 99403
Mailing Address: 1508 15TH ST CLARKSTON, WA 99403-2955

Agent

Name Role Address
BRAD E BATTERTON Agent 2750 HWY 95 S, MOSCOW, ID 83843

President

Name Role Address Appointed On
BRAD E BATTERTON President 2750 HIGHWAY 95 S, MOSCOW, ID 83843 2023-01-16

Filing

Filing Name Filing Number Filing date
Annual Report 0005959668 2024-11-04
Annual Report 0005495620 2023-12-04
Annual Report 0005071021 2023-01-16
Initial Filing 0004525936 2021-12-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346742216 1032500 2023-05-30 2750 HWY 95 S, MOSCOW, ID, 83843
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-05-30
Emphasis L: FORKLIFT, P: FORKLIFT
Case Closed 2023-10-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2023-08-17
Abatement Due Date 2023-09-13
Current Penalty 4922.4
Initial Penalty 7032.0
Final Order 2023-09-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards when operating a forklift without the use of a restraint device: a) Loading Area/Material Yard, on May 30, 2023; an employee operated a Hyster H90XMS, S/N: K005DO5794Y without the use of a personal restraint system.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 2023-08-17
Abatement Due Date 2023-09-13
Current Penalty 2952.6
Initial Penalty 4218.0
Final Order 2023-09-11
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.133(a)(1):The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a)On or about May 30, 2023 and times prior thereto, employees were not required to use eye protection while filling liquid petroleum (LP) tanks. NOTE: Abatement certification is required for this item.
339531907 1032500 2013-12-16 322 NORTH D STREET, GRANGEVILLE, ID, 83530
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-12-16
Emphasis L: FORKLIFT, P: FORKLIFT
Case Closed 2014-06-16

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100178 L03 I A
Issuance Date 2014-03-13
Abatement Due Date 2014-03-25
Current Penalty 1750.0
Initial Penalty 3500.0
Final Order 2014-03-26
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(3)(i)(A): Powered industrial truck operators did not receive training on operating instructions, warnings, and precautions for the types of truck the operator was authorized to operate: (a) Establishment: On or about December 16, 2013, and at times prior thereto, the employers training program for the powered industrial truck operators content consisted of formal discussion and a written test specifically designed for Rough Terrain Forklifts followed with hands on operation of a Hyster 50. Note: Abatement certification IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100178 L03 I H
Issuance Date 2014-03-13
Abatement Due Date 2014-03-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-03-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(3)(i)(H): The employer did not evaluate employees knowledge and/or understanding of the powered industrial truck capacity and/or capability. (a) Building and material storage yard: On or about December 16, 2013, and at times prior thereto, employees were unable to identify the location of the nameplate and/or the load capacity of the forklift in operation. Note: Abatement certification IS required
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100178 L03 I M
Issuance Date 2014-03-13
Abatement Due Date 2014-03-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-03-26
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(3)(i)(M): Powered industrial truck operators did not receive initial training in the following topics to include but not limited to operating instructions, warnings, or precautions listed in the operators manual for the types of vehicle that the employee is being trained to operate: (a) Building and materials storage yard: On or about December 16, 2013, and at times prior thereto, the employer did not have the operators manual for the Hyster 50 Fortis lift truck. (b) Building and materials storage yard: On or about Decem ber 16, 2013, and at times prior thereto, the employer did not have the operators manual for the Hyster 80 lift truck. Note: Abatement certification IS required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19100303 G01
Issuance Date 2014-03-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-03-26
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: (a) Building material yard, storage shed: On or about December 16, 2013, and at times prior thereto, an electrical panel was blocked with storage materials. Note: Abatement certification IS NOT required for this item.
Citation ID 02002
Citaton Type Other
Standard Cited 19100305 G02 III
Issuance Date 2014-03-13
Abatement Due Date 2014-03-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-03-26
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints and/or terminal screws. (a) Job Site: On or about December 16, 2013, and at times prior thereto, an extension cord utilized to plug the a forklift into an engine block heater was in need of strain relief. Note: Abatement certification IS required for this item.

Date of last update: 24 Mar 2025

Sources: Idaho Secretary of State