347264400
|
1032500
|
2024-02-07
|
7534 CULTURE WAY, COEUR D ALENE, ID, 83815
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-02-07
|
Emphasis |
N: FALL
|
Case Closed |
2024-06-25
|
Related Activity
Type |
Referral |
Activity Nr |
2149795 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1726452 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2024-04-18 |
Abatement Due Date |
2024-05-14 |
Current Penalty |
3042.0 |
Initial Penalty |
6084.0 |
Final Order |
2024-05-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13):The top or top step of a stepladder was used as a step: a) On February 7, 2024, employees used an 8 foot A-Frame ladder to access the top plate of an interior wall. NOTE: Abatement certification is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-04-18 |
Abatement Due Date |
2024-05-14 |
Current Penalty |
5070.0 |
Initial Penalty |
14195.0 |
Final Order |
2024-05-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b). a) On February 7, 2024, employees were exposed to fall hazards of 23 feet to the ground below while setting trusses on the second-floor. Absolute Quality Construction, Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard (1926.501(b)(1)), which was contained in OSHA inspection number #1377912, citation number 1, item number 4 and was affirmed as a final order on 03/29/2019, with respect to a workplace located at 315 E. Coeur D'Alene Drive Coeur D Alene, Idaho NOTE: Abatement certification and documentation is required for this item. |
|
|
343779120
|
1032500
|
2019-02-07
|
315 E. COEUR D'ALENE DRIVE, COEUR D ALENE, ID, 83814
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-02-07
|
Case Closed |
2019-09-13
|
Related Activity
Type |
Referral |
Activity Nr |
1426086 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1377932 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2019-03-05 |
Abatement Due Date |
2019-03-29 |
Current Penalty |
0.0 |
Initial Penalty |
1705.0 |
Final Order |
2019-04-03 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions. (a) Lake Side Apartments: On or about February 7, 2019, and at times prior thereto, employees performing framing activities which required the use of a pneumatic nail guns did not have safety glasses. Note: Abatement certification IS required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2019-03-05 |
Abatement Due Date |
2019-03-29 |
Current Penalty |
0.0 |
Initial Penalty |
1705.0 |
Final Order |
2019-04-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) Lake Drive Apartments: On or about February 7, 2019 and at times prior thereto, employees exposed to possible head injury from falling or flying objects and/or from impact with equipment, hand tools, were not wearing hard hats. Note: Abatement certification IS required for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2019-03-05 |
Abatement Due Date |
2019-03-29 |
Current Penalty |
0.0 |
Initial Penalty |
3978.0 |
Final Order |
2019-04-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: (a) Lake Drive Apartments: On or about February 7, 2016, and at times prior, an employee working out of a Genie S-85 aerial lift 4x4 was not wearing fall protection and exposed to an approximate 56 foot fall hazard. Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated. Note: Abatement certification and documentation ARE required for this item. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2019-03-05 |
Abatement Due Date |
2019-03-29 |
Current Penalty |
3978.0 |
Initial Penalty |
3978.0 |
Final Order |
2019-04-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Employees on walking/working surfaces with an unprotected side and/or edge which is 6 feet or more above a lower level were not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems: a) Lake Side Apartments: On or about February 7, 2019, employees performing framing activities were exposed to a fall hazard while working on a commercial structure without a means of fall protection. Employees were exposed to fall hazards from approximately 56 feet. Note: Abatement certification and documentation ARE required for this item., |
|
|
339659609
|
1032500
|
2014-02-27
|
4295 SAWBLADE LN, COEUR D ALENE, ID, 83814
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-02-27
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2014-06-17
|
Related Activity
Type |
Inspection |
Activity Nr |
962425 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260403 I02 I |
Issuance Date |
2014-04-04 |
Abatement Due Date |
2014-04-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. (a) Upstairs of building AMR 03: On or about February 27, 2014 and at times prior thereto, employees were operating a Mag 77 circular saw that had been plugged in to a 120v outlet that was not protected from contact by an outlet cover. Note: Abatement certification is required for this item. |
|
|
331065300
|
1032500
|
2011-09-13
|
7887 BAILLIE STREET, DALTON GARDENS, ID, 83815
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-09-13
|
Emphasis |
L: FALL
|
Case Closed |
2013-07-10
|
Related Activity
Type |
Referral |
Activity Nr |
81045 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2012-01-24 |
Abatement Due Date |
2012-01-31 |
Current Penalty |
900.0 |
Initial Penalty |
1800.0 |
Final Order |
2012-02-23 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. Job Site: On or about September 13, 2011, and at times prior thereto, |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2012-01-24 |
Abatement Due Date |
2012-01-31 |
Current Penalty |
1800.0 |
Initial Penalty |
3600.0 |
Final Order |
2012-02-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) Job Site: On or about September 13, 2011, and at times prior thereto, three employees without a means of fall protection were observed walking on interior structural beams and/or climbing the framed structural walls while performing framing activities. Note: Abatement certification IS NOT required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2012-01-24 |
Abatement Due Date |
2012-02-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-02-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. Job Site: On or about September 13, 2011, and at times prior thereto, employees were unable to recognize the hazards of falling and were not equipped with appropriate instruction in the procedures to be followed in order to minimize these hazards. Note: Abatement certification IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260302 B06 |
Issuance Date |
2012-01-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-02-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.302(b)(6): The use of hoses for hoisting or lowering tools was permitted. (a) Job Site: On or about September 13, 2011, an employee was observed lowering a pneumatic nail gun to the ground surface by use of the hose. Note: Abatement certification IS NOT required for this item. |
|
|