Search icon

FALCON FRAMERS LLC.

Company Details

Name: FALCON FRAMERS LLC.
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 26 Jan 2015 (10 years ago)
Financial Date End: 31 Jan 2026
Entity Number: 447415
Place of Formation: IDAHO
File Number: 447415
ZIP code: 83704
County: Ada County
Principal Address: 2280 N MAPLE GROVE RD BOISE, ID 83704
Mailing Address: AARON SNOW STE 101 8324 W NORTHVIEW ST BOISE, ID 83704-7185

Agent

Name Role Address
AARON SNOW Agent 12254 W. CASTLEWOOD, BOISE, ID 83709

Manager

Name Role Address Appointed On
Aaron Snow Manager 8324 W NORTHVIEW ST, BOISE, ID 83704 2021-04-14

Filing

Filing Name Filing Number Filing date
Annual Report 0006045068 2025-01-03
Annual Report 0005498365 2023-12-04
Application for Reinstatement 0005201572 2023-04-21
Dissolution/Revocation - Administrative 0005197382 2023-04-13
Statement of Change of Business Mailing Address 0004636495 2022-03-07
Annual Report 0004605117 2022-02-11
Statement of Change of Business Mailing Address 0004248034 2021-04-14
Application for Reinstatement 0004248041 2021-04-14
Dissolution/Revocation - Administrative 0004239993 2021-04-08
Annual Report 0003775583 2020-02-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345275267 1032500 2021-04-28 FIVE MILE RD AND MCMILLAN RD, BOISE, ID, 83704
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Case Closed 2021-04-28

Related Activity

Type Complaint
Activity Nr 1760441
Safety Yes
345039465 1032500 2020-11-24 2205 E RIVERSIDE DRIVE, EAGLE, ID, 83616
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2020-11-24
Emphasis L: FALL
Case Closed 2021-09-30

Related Activity

Type Complaint
Activity Nr 1691995
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260095 D01
Issuance Date 2021-02-16
Abatement Due Date 2021-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-03-16
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(d)(1):Except as provided by paragraphs (d)(2) through (d)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, was not provided by the employer at no cost to employees. (a) On November 24, 2020; the employer does not provide head protection at no cost to employees performing framing activities. Employees are exposed to head injuries from impact, flying objects, or from falling objects while underneath overhead work. Employees purchase their own head protection. (b) On November 24,2020; the employer does not provide eye protection at no cost to employees performing framing activities. Employees are exposed to eye injuries while using equipment such as, but not limited to pneumatic nail guns and claw hammers. Employees purchase their own eye protection. NOTE: Abatement certification is required for this item.
342285509 1032500 2017-04-27 1421 PROMONTORY ROAD, BOISE, ID, 83702
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-04-27
Case Closed 2019-01-30

Related Activity

Type Complaint
Activity Nr 1205453
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 D06 I
Issuance Date 2017-05-24
Abatement Due Date 2017-05-31
Current Penalty 3500.0
Initial Penalty 3803.0
Contest Date 2017-06-19
Final Order 2018-07-25
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(6)(i): When a snaphook is not a locking type and not designed for the following connections, snaphooks were engaged directly to webbing, rope or wire rope: a) North/south side of roof: On or about April 27, 2017 and at times prior thereto an employee performing framing activities improperly used components of a fall protection system. A lanyard and snaphook were wrapped around a wooden truss and then hooked directly back on to the rope lanyard. This was used as the anchor point for the employee's personal fall protection. b) North/south side of roof: On or about April 27, 2017 and at times prior an employee performing framing activities improperly used components of a fall protection system. A snaphook and retractable cloth lanyard were wrapped around a wooden truss and then hooked directly back on to the cloth lanyard. This was used as the anchor point for the employee's personal fall protection. Note) Certification and documentation of corrective action ARE required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 D15 II
Issuance Date 2017-05-24
Abatement Due Date 2017-06-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-06-19
Final Order 2018-07-25
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment were not installed, and used under the supervision of a qualified person: a) North and south side of main roof: On or about April 27, 2017 and at times prior thereto components of the personal fall protection system were not used in accordance with the manufacturers instructions. A snaphook was attached directly to a shock absorbing rope lanyard. b) North and south side of main roof: On or about April 27, 2017 and at times prior thereto components of the personal fall protection system were not used in accordance with the manufacturers instructions. A snaphook was attached directly to a Miller Scorpion shock absorbing retractable cloth lanyard. Note) Certification and documentation ARE required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260503 A02 III
Issuance Date 2017-05-24
Abatement Due Date 2017-06-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-06-19
Final Order 2018-07-25
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On or about April 27, 2017 and at times prior thereto employees performing framing activities did not recognize the hazard of working on a flat roof deck without a guardrail system in place. The employees did not take any action to minimize or eliminate the hazard. b) Jobsite: On or about April 27, 2017 and at times prior thereto employees performing framing activities did not recognize the improper use of components as part of their fall protection system. Snaphooks attached directly to shock absorbing rope lanyards were used as anchor points. The employees did not take any action to correct the hazard. Note) Certification and documentation of corrective action are required for this item.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2017-05-24
Abatement Due Date 2017-05-31
Current Penalty 3500.0
Initial Penalty 7605.0
Contest Date 2017-06-19
Final Order 2018-07-25
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) Jobsite: On April 27, 2017 and at times prior thereto employees performed sheathing activities on a 10 in 12 pitched roof without a fall protection system in place. Employees were exposed to a 22 foot fall hazard from eave to ground. b) Jobsite: On April 27, 2017 and at times prior thereto employees performed framing activities on a flat roof deck. A guardrail or other fall protection system was not in place. Employees were exposed to a 16 foot fall hazard from the roof deck to the concrete and ground below. c) Jobsite: On April 27, 2017 and at times prior thereto employees performed framing activities on the second floor near window openings. A guardrail across the opening or another fall protection system was not in place. Employees were exposed to a 16 foot fall hazard to the ground below. Note) Certification and documentation are required for this item. Falcon Framers, LLC was previously cited for a violation of this occupational safety standard, 29CFR 1926.501(b)(13), which was contained in OSHA inspection number 962580, citation number 1, item number 1, and was affirmed as a final order on May 30, 2014, with respect to a workplace located at 963 West Laughton Drive, Meridian, ID 83642.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
8611297006 2020-04-08 1087 PPP 2280 N MAPLE GROVE, BOISE, ID, 83704
Loan Status Date 2021-03-09
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 144845
Loan Approval Amount (current) 144845
Undisbursed Amount 0
Franchise Name -
Lender Location ID 87893
Servicing Lender Name Glacier Bank
Servicing Lender Address 202 Main St, KALISPELL, MT, 59901-4454
Rural or Urban Indicator U
Hubzone N
LMI Y
Business Age Description Existing or more than 2 years old
Project Address BOISE, ADA, ID, 83704-0100
Project Congressional District ID-02
Number of Employees 25
NAICS code 236117
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 87893
Originating Lender Name Glacier Bank
Originating Lender Address KALISPELL, MT
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 146027.57
Forgiveness Paid Date 2021-02-10

Date of last update: 08 Apr 2025

Sources: Idaho Secretary of State