Search icon

Framing bros llc

Company Details

Name: Framing bros llc
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 19 Oct 2021 (4 years ago)
Financial Date End: 31 Oct 2025
Entity Number: 4450902
Place of Formation: IDAHO
File Number: 786954
ZIP code: 83642
County: Ada County
Principal Address: SINDY RAMIREZ 858 3313 W CHERRY LANE MERIDIAN, ID 83642
Mailing Address: SINDY RAMIREZ 2928 495 DEINHARD LN MCCALL, ID 83638

Agent

Name Role Address
Sindy Elizabeth Orellana ramirez Agent 13974 RUSTIC RD, MCCALL, ID 83638

Member

Name Role Address Appointed On Resigned On
Adrian Raredes Member 3313 W CHERRY LANE, MERIDIAN, ID 83642 2022-10-21 2023-10-11
adrian brigil paredes Member 495 DEINHARD, MCCALL, ID 83638 2023-10-11 No data

Filing

Filing Name Filing Number Filing date
Annual Report 0005931743 2024-10-07
Annual Report 0005438175 2023-10-11
Annual Report 0004958819 2022-10-21
Initial Filing 0004450902 2021-10-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347524001 1032500 2024-05-30 1919 LONE TREE ROAD, DONNELLY, ID, 83615
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-05-30
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2169253
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-08-19
Abatement Due Date 2024-08-23
Current Penalty 1300.0
Initial Penalty 2074.0
Final Order 2024-09-25
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On May 30, 2024, and times prior employees did not wear hard hats while working under a crane that was overhead installing wooden trusses. Note) Abatement certification is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-08-19
Abatement Due Date 2024-08-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-25
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On May 29, 2024, and times prior employees performing framing activities using pneumatic nail guns were not wearing safety glasses. Note) Certification of corrective action is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-08-19
Abatement Due Date 2024-08-23
Current Penalty 2175.0
Initial Penalty 3457.0
Final Order 2024-09-25
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501: a) On May 30, 2024, and times prior, employees performed framing activities on a flat deck area. The employees were exposed to a 12.5-foot fall hazard to a lower level or the ground below. b) On May 30, 2024, and times prior, an employee performed framing activities while positioned on a wooden truss. The employee was exposed to a 23-foot fall hazard to the lower level. Note) Corrective action is required for item b.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-08-19
Abatement Due Date 2024-09-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-25
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On May 30, 2024, employees performing framing activities on a flat deck area without fall protection were exposed to 12.5-foot fall hazards. The employees did not recognize the hazard or take action to minimize their exposure. b) On May 30, 2024, an employee performing framing activities while positioned on an installed truss assembly without fall protection was exposed to a 23-foot fall hazard. The employee did not recognize the hazard or take action to minimize the exposure. Note) Certification of corrective action is needed for this item.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-08-19
Current Penalty 1750.0
Initial Penalty 2765.0
Final Order 2024-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On May 30, 2024, and times prior employees used an extension ladder that did not extend beyond the landing surface of the flat deck work area. Note) Fixed during inspection.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261060 A01 III
Issuance Date 2024-08-19
Abatement Due Date 2024-09-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1)(iii): The employer did not provide a training program for each employee in the proper construction, use, placement, and care in handling of all stairways and ladders; a) On May 30, 2024, and at times prior employees performing framing activities used an improperly positioned extension ladder for access to the work area. The employees did not recognize the hazard or take action to minimize their exposure. Note) Certification of corrective action is needed for this item.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261412 H
Issuance Date 2024-08-19
Abatement Due Date 2024-10-04
Current Penalty 1275.0
Initial Penalty 2074.0
Final Order 2024-09-25
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1412(h): Equipment that had been idle for 3 months or more was not inspected by a qualified person in accordance with the requirements of paragraph (e) of this section before initial use: a) On May 30, 2024, and times prior the Terex Stinger RS6000 truck mounted crane was used to place trusses at a single-family residential job site. The crane had not been inspected prior to being put into service. Note) Certification of corrective action is required for this item.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261427 A01 I
Issuance Date 2024-08-19
Abatement Due Date 2024-10-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-25
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1427(a)(1)(i): The employer did not ensure that, prior to operating any equipment covered under subpart CC the person operating the equipment was licensed by a government entity for operation of the equipment within that entity's jurisdiction: a) On May 30, 2024, and times prior a Terex Stinger RS6000 truck mounted crane was used to place trusses at a single family residential job site. The employee operating the crane lacked the proper certification needed to operate a crane of this type and capacity. Note) Certification of corrective action is required for this item.

Date of last update: 16 Apr 2025

Sources: Idaho Secretary of State