Search icon

C&E Construction Services LLC

Company Details

Name: C&E Construction Services LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 23 Sep 2021 (4 years ago)
Financial Date End: 30 Sep 2025
Entity Number: 4426376
Place of Formation: IDAHO
File Number: 783346
ZIP code: 83401
County: Bonneville County
Principal Address: 1405 KEARNEY ST IDAHO FALLS, ID 83401
Mailing Address: PREMIER PROFESSIONAL SERVICES INC 401 MAY ST IDAHO FALLS, ID 83401-2619

Agent

Name Role Address
Premier Professional Services INC Agent 401 MAY ST, IDAHO FALLS, ID 83401-2619

Member

Name Role Address Appointed On
Ramon E Medina Member 1405 KEARNEY STREET, IDAHO FALLS, ID 83401 2023-08-24

Manager

Name Role Address Appointed On
Carmen Medina Manager 1405 KEARNEY ST, IDAHO FALLS, ID 83401 2021-12-10

Filing

Filing Name Filing Number Filing date
Annual Report 0005865627 2024-08-19
Annual Report 0005371255 2023-08-24
Annual Report 0004865856 2022-08-19
Amendment to Certificate 0004525256 2021-12-10
Initial Filing 0004426376 2021-09-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346102684 1032500 2022-07-26 CATALINA AVENUE, IDAHO FALLS, ID, 83401
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-07-26
Emphasis N: HEATNEP, L: FALL, L: FORKLIFT

Related Activity

Type Referral
Activity Nr 1924589
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 C02 V
Issuance Date 2022-07-27
Abatement Due Date 2022-08-08
Current Penalty 2610.0
Initial Penalty 3729.0
Final Order 2022-08-26
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and/or the fork-lift was moved horizontally while the platform was occupied: (a) A JLG 6042 rough-terrain forklift was used to elevate workers on an uneven stack of 4' x 8' sheathing to install sheathing and other framing. The sheathing was not a platform designed for forklift use and was not secured to the forks. Workers were elevated approximately 13 feet above the ground. NOTE: Certification of corrective action (abatement) is required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260602 D
Issuance Date 2022-07-27
Abatement Due Date 2022-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-08-26
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178 and as referenced by the note contained in 1926.602(d). (a) A JLG 6042 rough-terrain forklift was used on the jobsite, including to elevate workers on a stack of sheathing to install sheathing and other framing. The operator had not received training, evaluation and certification as specified in 29 CFR 1910.178 paragraph (l). NOTE: Certification of corrective action (abatement) is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2022-07-27
Abatement Due Date 2022-08-08
Current Penalty 2610.0
Initial Penalty 3729.0
Final Order 2022-08-26
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) Employees elevated on an uneven stack of 4' x 8' OSB to a height of approximately 13 feet were not provided or using any form of fall protection. NOTE: Certification of corrective action (abatement) is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-07-27
Abatement Due Date 2022-08-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-08-26
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Employees engaged in framing and sheathing activities were not provided or using any form of fall protection when working on an approximate 5 in 12 sloped roof at a height of 11 feet 8 inches near the eave or more towards the peak. NOTE: Certification of corrective action (abatement) is required for this item.

Date of last update: 16 Apr 2025

Sources: Idaho Secretary of State