Search icon

Trigon Roofing Inc.

Company Details

Name: Trigon Roofing Inc.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Inactive-Dissolved (Administrative)
Date of registration: 08 Sep 2021 (4 years ago)
Financial Date End: 30 Sep 2024
Date dissolved: 13 Dec 2024
Entity Number: 4411056
Place of Formation: IDAHO
File Number: 780891
ZIP code: 83634
County: Ada County
Mailing Address: 355 W SNOWY OWL ST KUNA, ID 83634-3566

Agent

Name Role Address
Marco Mendoza Agent 355 W SNOWY OWL ST, KUNA, ID 83634

Filing

Filing Name Filing Number Filing date
Dissolution/Revocation - Administrative 0006024682 2024-12-13
Application for Reinstatement 0005811752 2024-07-08
Dissolution/Revocation - Administrative 0005024991 2022-12-09
Initial Filing 0004411056 2021-09-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347354763 1032500 2024-03-18 1734 W STATE STREET, BOISE, ID, 83702
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-03-18
Emphasis L: FALL, N: FALL

Related Activity

Type Inspection
Activity Nr 1735468
Safety Yes
Type Referral
Activity Nr 2142514
Safety Yes
Type Inspection
Activity Nr 1735472
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2024-04-18
Current Penalty 2074.0
Initial Penalty 2074.0
Final Order 2024-05-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system. a) On or about March 18, 2024, and at times prior to; employees working on a 3:12 pitched roof installing shingles were exposed to a fall hazard approximately 13.5 feet to the concrete sidewalk below.
347246498 1032500 2024-01-31 ROE STREET TOWNHOMES, BOISE, ID, 83714
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2024-01-31
Emphasis L: FALL

Related Activity

Type Complaint
Activity Nr 2126240
Safety Yes
Type Inspection
Activity Nr 1724654
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-06-06
Abatement Due Date 2024-06-18
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Bldg. 22-02854: On January 31, 2024, and at times prior to; the employer failed to ensure that its employees were protected from falls while installing roofing shingles. Employees were exposed to falls ranging from approximately 10 feet to 22 feet on a 6x12 pitch roof. Note* Abatement certification is required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-06-06
Abatement Due Date 2024-06-18
Current Penalty 2765.0
Initial Penalty 2765.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allowed, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Back of Bldg. 22-02854: On January 31, 2024, employees installing roofing shingles from approximately 10 feet to 22 feet on a 6x12 pitch roof used a ladder to access the second-story roof line from the first-story. The ladder extended approximately 6-8" above the roof line. Note* Abatement certification is required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2024-06-06
Abatement Due Date 2024-06-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-07-22
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) Back of Bldg. 22-02854: On January 31, 2024, and at times prior to; employees installing roofing shingles from approximately 10 feet to 22 feet on a 6x12 pitch roof used a collapsed A-frame ladder which was not designed to be used as an extension ladder to access the second-story roof from the first-story. b) Front of Bldg. 22-02854: On January 31, 2024, and at times prior to; employees installing roofing shingles from approximately 10 feet to 22 feet on a 6x12 pitch roof used a collapsed A-frame ladder which was not designed to be used as an extension ladder to access the second-story roof from the first-story. Note* Abatement certification is required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2024-06-06
Abatement Due Date 2024-06-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-07-22
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a) Back of Bldg. 22-02854: On January 31, 2024, and at times prior to; employees installing roofing shingles from approximately 10 feet to 22 feet on a 6x12 pitch roof used a collapsed A-frame ladder which was not designed to be used as an extension ladder to access the second-story roof from the first-story. b) Front of Bldg. 22-02854: On January 31, 2024, and at times prior to; employees installing roofing shingles from approximately 10 feet to 22 feet on a 6x12 pitch roof used a collapsed A-frame ladder which was not designed to be used as an extension ladder to access the second-story roof from the first-story. Note* Abatement certification is required for this item.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19261053 B09
Issuance Date 2024-06-06
Abatement Due Date 2024-06-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-07-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear: a) RFront of Bldg. 22-02854: On January 31, 2024, and at times prior to; employees were installing roofing shingles from approximately 17 feet to 22 feet on a 6x12 pitch roof. Thin roofing material product boxes were positioned around the base of the ladder positioned on the first-story roof, to prevent the ladder from slipping. Note* Abatement certification is required for this item.

Date of last update: 16 Apr 2025

Sources: Idaho Secretary of State