Name: | RAY DAY JR. LOGGING, INC. |
Jurisdiction: | Idaho |
Legal type: | General Business Corporation (D) |
Status: | Active-Good Standing |
Date of registration: | 19 Jul 2002 (23 years ago) |
Financial Date End: | 31 Jul 2025 |
Entity Number: | 440887 |
Place of Formation: | IDAHO |
File Number: | 440887 |
ZIP code: | 83537 |
County: | Latah County |
Mailing Address: | 1005 FERN HILL RD KENDRICK, ID 83537-9513 |
Name | Role | Address |
---|---|---|
KRISTY L DAY | Agent | 1005 FERN HILL RD, KENDRICK, ID 83537 |
Name | Role | Address | Appointed On |
---|---|---|---|
Ray Day | President | 1005 FERN HILL ROAD, KENDRICK, ID 83537 | 2021-07-07 |
Filing Name | Filing Number | Filing date |
---|---|---|
Application for Reinstatement | 0005940194 | 2024-10-12 |
Dissolution/Revocation - Administrative | 0005938604 | 2024-10-11 |
Application for Reinstatement | 0005429139 | 2023-10-04 |
Dissolution/Revocation - Administrative | 0005428542 | 2023-10-04 |
Annual Report | 0004946903 | 2022-10-07 |
Annual Report | 0004336696 | 2021-07-07 |
Annual Report | 0003904995 | 2020-06-09 |
Annual Report | 0003666474 | 2019-11-04 |
Annual Report | 0002871356 | 2018-07-10 |
Annual Report | 0002871354 | 2017-07-31 |
FAIN | Awarding Agency | Assistance Listings | Start Date | End Date | Description | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3572285004 | Small Business Administration | 59.012 - 7(A) LOAN GUARANTEES | No data | No data | TO AID SMALL BUSINESSES WHICH ARE UNABLE TO OBTAIN FINANCING IN THE PRIVATE CREDIT MARKETPLACE | |||||||||||||||||
|
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340724863 | 1032500 | 2015-06-10 | BLOODY CAMP SALE, KENDRICK, ID, 83537 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 988488 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100266 D07 I |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-12 |
Current Penalty | 3500.0 |
Initial Penalty | 3500.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.266(d)(7)(i): Hand signals or audible contact, such as but not limited to, whistles, horns, or radios, were not utilized whenever noise, distance, restricted visibility, or other factors prevent clear understanding of normal voice communications between employees: a) Bloody Camp Sale: On May 28, 2015 an employee failed to communicate in any manner with other employees prior to falling a tree. Note) Certification of corrective action IS required for this item. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100266 H01 I |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 3500.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.266(h)(1)(i): Trees were felled in a manner that created a hazard for an employee, such as but not limited to, striking a rope, cable, power line, or machine: a) Bloody Camp Sale: On May 28, 2015 an employee failed to ensure the area was clear before falling a tree in a manner that allowed it to strike an elevated portion of the skyline. Note) Certification of corrective action IS required for this item. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-06-09 |
Emphasis | L: LOGGING |
Case Closed | 2016-02-12 |
Related Activity
Type | Referral |
Activity Nr | 988488 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100023 A08 I |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-12 |
Current Penalty | 1250.0 |
Initial Penalty | 2380.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.23(a)(8)(i): Every floor hole into which persons can accidently walk was not guarded by a standard railing with standard toe board on all exposed sides: a) Maintenance shop, second floor: On June 9, 2015 and at times prior thereto, a guardrail did not extend the entire length of the stairway opening, adjacent to the upper portion of the stairway. The unprotected floor opening created a tripping hazard at the top of the stairs. Note) Certification of corrective action IS required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100184 E01 |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-26 |
Current Penalty | 1250.0 |
Initial Penalty | 2380.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.184(e)(1): Alloy steel chain slings did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) Maintenance shop: On June 9, 2015 and at times prior thereto chain slings were used to lift and hold items, including but not limited to, logging machinery, while employees performed various maintenance activities on the hoisted item. Note) Certification of corrective action IS required for this item. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100157 C01 |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.157(c)(1): The employer provided portable fire extinguishers that were not mounted, and located so that they were readily accessible to employees without subjecting the employees to possible injury: a) Maintenance shop: On June 9, 2015 and at times prior thereto a welding table blocked easy access to a portable fire extinguisher mounted on the wall behind it. Note) Certification of corrective action IS required for this item. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100244 A01 II |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.244(a)(1)(ii): The rated load was not legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means: a) Portable jack stands used in the maintenance shop. Note) Certification of corrective action IS required for this item. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19100244 A02 VI A |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.244(a)(2)(vi)(a): Each jack was not thoroughly inspected for constant or intermittent use at one locality, once every 6 months: a) Maintenance shop: On June 9, 2015 and at times prior thereto an inspection program was not in place for the floor jacks that were used in various maintenance activities. Note) Certification of corrective actions IS required for this item. |
Citation ID | 02004 |
Citaton Type | Other |
Standard Cited | 19100304 G05 |
Issuance Date | 2015-07-31 |
Abatement Due Date | 2015-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-08-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Maintenance shop: On June 9, 2015 and at times prior thereto the ground plug for the Jet belt sander/disc grinder was missing. b) Maintenance shop: On June 9, 2015 and at times prior thereto the ground plug for the Craftsman 8 inch bench grinder was missing. Note) Certification of corrective actions IS required for these items. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8387027207 | 2020-04-28 | 1094 | PPP | 1005 Fern Hill Rd, KENDRICK, ID, 83537-9709 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
784141 | Interstate | 2025-02-14 | 126946 | 2024 | 10 | 3 | Exempt For Hire | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 07 Apr 2025
Sources: Idaho Secretary of State