Name: | SOUTHERN IDAHO ROOFING LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 26 Nov 2014 (10 years ago) |
Financial Date End: | 30 Nov 2025 |
Date dissolved: | 22 Feb 2025 |
Entity Number: | 440879 |
Place of Formation: | IDAHO |
File Number: | 440879 |
ZIP code: | 83301 |
County: | Twin Falls County |
Principal Address: | 289 LOCUST ST S TWIN FALLS, ID 83301-7824 |
Name | Role | Address |
---|---|---|
JAMES BAMBURG | Agent | 289 LOCUST ST, TWIN FALLS, ID 83301 |
Name | Role | Address | Appointed On |
---|---|---|---|
James Bamburg | Member | 3822 GARY CIR, HANSEN, ID 83334 | 2020-10-03 |
Brittney Bamburg | Member | 289 LOCUST ST S, TWIN FALLS, ID 83301 | 2023-12-16 |
Filing Name | Filing Number | Filing date |
---|---|---|
Application for Reinstatement | 0006143820 | 2025-03-05 |
Dissolution/Revocation - Administrative | 0006117443 | 2025-02-22 |
Annual Report | 0005516459 | 2023-12-16 |
Annual Report | 0005013100 | 2022-12-05 |
Annual Report | 0004458488 | 2021-10-22 |
Annual Report | 0004021361 | 2020-10-03 |
Annual Report | 0003739610 | 2020-01-07 |
Annual Report | 0003308141 | 2018-10-12 |
Annual Report | 0002871334 | 2017-12-12 |
Annual Report | 0002871333 | 2016-11-29 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342796521 | 1032500 | 2017-11-29 | 561 SUN TERRACE RD, HOLLISTER, ID, 83301 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1288159 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2017-12-26 |
Abatement Due Date | 2018-01-23 |
Current Penalty | 1521.1 |
Initial Penalty | 2173.0 |
Final Order | 2018-01-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. (a) On November 29, 2017 employees using compressed air nail gun were not wearing protective eye wear. Note: Abatement certification is required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-12-26 |
Abatement Due Date | 2018-01-23 |
Current Penalty | 1521.1 |
Initial Penalty | 2173.0 |
Final Order | 2018-01-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On November 29, 2017 employees engaged in roofing activities were not protected from falls of 9.75 feet to hard packed earth and construction debris. Note: Abatement certification is required for this item. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2017-12-26 |
Abatement Due Date | 2018-01-23 |
Current Penalty | 1521.1 |
Initial Penalty | 2173.0 |
Final Order | 2018-01-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On November 29, 2017 the ladder used by employees to access and exit the roof only extended approximately 18" above the roof level. Note: Abatement certification is required for this item |
Date of last update: 07 Apr 2025
Sources: Idaho Secretary of State