Name: | ALVARADO Construction LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Active-Existing |
Date of registration: | 30 Sep 2014 (11 years ago) |
Financial Date End: | 30 Sep 2025 |
Entity Number: | 434989 |
Place of Formation: | IDAHO |
File Number: | 434989 |
ZIP code: | 83651 |
County: | Canyon County |
Principal Address: | 723 LONG VALLEY ST NAMPA, ID 83651 |
Mailing Address: | 16223 N DIAMOND PEAK DR NAMPA, ID 83651 |
Name | Role | Address |
---|---|---|
JULIO ALVARADO | Agent | 16223 N DIAMOND PEAK DR, NAMPA, ID 83651 |
Name | Role | Address | Appointed On | Resigned On |
---|---|---|---|---|
Kenia D Reyes | Member | 723 LONG VALLEY ST, NAMPA, ID 83687-8674 | 2020-09-28 | 2020-12-15 |
Julio Alvarado | Member | 16223 N DIAMOND PEAK DR, NAMPA, ID 83651 | 2024-11-08 | No data |
Filing Name | Filing Number | Filing date |
---|---|---|
Annual Report | 0005974539 | 2024-11-08 |
Application for Reinstatement | 0005374133 | 2023-08-29 |
Dissolution/Revocation - Administrative | 0004539625 | 2021-12-24 |
Application for Reinstatement | 0004101196 | 2020-12-15 |
Dissolution/Revocation - Administrative | 0004092370 | 2020-12-08 |
Amendment to Certificate | 0004011166 | 2020-09-28 |
Change of Registered Office/Agent/Both (by Entity) | 0004011157 | 2020-09-24 |
Amendment to Certificate | 0003622247 | 2019-09-15 |
Application for Reinstatement | 0003620440 | 2019-09-12 |
Dissolution/Revocation - Administrative | 0003392895 | 2019-01-10 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338908700 | 1032500 | 2013-02-13 | 1120 W SHERINGTON DR., EAGLE, ID, 83616 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 804839 |
Safety | Yes |
Type | Inspection |
Activity Nr | 890909 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-04-11 |
Abatement Due Date | 2013-05-07 |
Current Penalty | 1360.0 |
Initial Penalty | 1360.0 |
Final Order | 2013-05-06 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a) North side roof area: On February 13, 2013, and times prior thereto, an employee was installing sheathing and framing on a 8 inches in 12 inches pitch roof without fall protection. Note: Abatement certification is required for this item. |