Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-02-21
|
Emphasis |
N: FALL
|
Related Activity
Type |
Referral |
Activity Nr |
2151096 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1729232 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1729238 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2024-04-15 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
1555.5 |
Initial Penalty |
2074.0 |
Final Order |
2024-08-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On or before February 21, 2024, employees working on the ground level of the site were working directly below an employee placing sheeting on the roof. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-04-15 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-08-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On February 21, 2024 and times prior, employees using a pneumatic nail gun to install sheathing and brackets to ceiling framing were not wearing eye protection. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-04-15 |
Abatement Due Date |
2024-04-25 |
Current Penalty |
2073.75 |
Initial Penalty |
2765.0 |
Final Order |
2024-08-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On February 21, 2024, employees were exposed to falls between 10 and 12 feet to the ground below while performing framing activities. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2024-04-15 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
3111.0 |
Initial Penalty |
4148.0 |
Final Order |
2024-08-22 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a)On February 21, 2024 employees were using the top step of an A-Frame ladder to access and exit the roof while performing framing activities. (b) On February 21, 2024, an employee worked from the top step of an A-Frame ladder to nail brackets to the rafters. Abatement Note: Abatement certification is required for this item: See enclosed "Certification of Corrective Actions Worksheet." |
|
|